Tiguan Mk2 (2016-2023): Air conditioning systems with R1234yf refrigerant - General information
Also for this vehicle: Tiguan (5N1) L4-2.0L Turbo (CCTA) (2011), Tiguan 4Motion (5N1) L4-2.0L Turbo (CCTA) (2009), Tiguan Mk1 (2007-2016).
Engine
Transmission
Brakes
Steering & suspension
Heating & A/C
Electrical
Body & interior
Choose Sections to see everything in a chapter, or a chapter title to start at its first page.
Engine
Transmission
Steering and suspension
Brakes
Electrical
Heating and air conditioning
- 12Air conditioning systems with R1234yf refrigerant - General informationAir conditioning systems with R1234yf refrigerant - General information: Sections
Safety instructions8 pages
- Safety instructions
- Safety precautions when working on air conditioning systems
- Safety precautions when handling refrigerants
- Safety precautions for working on vehicles with start/stop system
- Safety measures when using air conditioner service station
- Safety measures for working on vehicles with high-voltage system
- Safety precautions when working in vicinity of high-voltage components
- Safety measures when using pressure vessels
Technical and physical principles29 pages
- Technical and physical principles
- Basics of air conditioning
- Physical principles of air conditioning system
- Pressure and boiling point of refrigerant
- Vapour pressure table for refrigerant
- Physical properties
- Refrigerant R1234yf
- Potential dangers of R1234yf refrigerant
- Physical and chemical properties of R1234yf refrigerant
- Critical point
- Environmental aspects of refrigerant R1234yf
- Trade names and designations of refrigerant R1234yf
- Colour and odour of R1234yf refrigerant
- Vapour pressure of R1234yf refrigerant
- Physical properties of R1234yf refrigerant
- How R1234yf refrigerant responds with metals and plastics
- Critical temperature / critical pressure of R1234yf refrigerant
- Water content of R1234yf refrigerant
- Flammability / decomposition of R1234yf refrigerant
- Charge factor of R1234yf refrigerant
- Evidence of leaks in a refrigerant circuit with R1234yf refrigerant
- Analysis of R1234yf refrigerant
- Returning contaminated R1234yf refrigerant for analysis, processing or disposal
- Product characteristics
- Function and role of air conditioning system
- Principle of operation
- Comfort
- Environmental aspects
- Additional information
Refrigerant circuit62 pages
- Refrigerant circuit
- System overview - refrigerant circuit
- System overview - refrigerant circuit with expansion valve and receiver
- System overview - refrigerant circuit with restrictor and receiver
- System overview - refrigerant circuit with electrically driven air conditioner compressor (with and without battery cool
- General description - components of refrigerant circuit
- Layout and function of refrigerant circuit
- Mechanically driven air conditioner compressor
- Electrically driven air conditioner compressor for hybrid vehicles
- Condenser
- Evaporator
- Reservoir
- Heat exchanger for heat pump mode
- Liquid receiver
- Restrictor
- Receiver
- Expansion valve (with and without shut-off valve)
- Refrigerant shut-off valves
- Refrigerant line with internal heat exchanger
- Quick release couplings of refrigerant lines
- Seal
- Pipes and hoses in refrigerant circuit
- High pressure safety valve
- Non-return valves
- Quick-release coupling connections in refrigerant circuit
- Connections to valves for switches in the refrigerant circuit
- Pressure senders and switches in refrigerant circuit
- Refrigerant pressure and temperature sender
- Air conditioner compressor regulating valve N280
- Refrigerant temperature sender
- Possible complaints
- Prerequisites for investigating a complaint
- Possible complaints
- Smells from heater and air conditioner unit
- Investigating leaks
- General information about investigating leaks in refrigerant circuit
- Searching for leaks in refrigerant circuits using an electronic leak detector
- Searching for leaks with UV leak detection system
- Investigating leaks by means of vacuum check with air conditioner service station or pressure check
- Renewing components
- General information about renewing components
- Renewing leaking or damaged components of empty refrigerant circuit (apart from air conditioner compressor and receiver)
- Renewing leaking or damaged components of charged refrigerant circuit (apart from air conditioner compressor and receive
- Renewing air conditioner compressor with no need to clean refrigerant circuit
- Renewing air conditioner compressor due to leaks or internal damage
- Renewing desiccant cartridge / receiver after cleaning refrigerant circuit
- Renewing receiver with no need to clean refrigerant circuit
- Renewing desiccant cartridge / desiccant bag with no need to clean refrigerant circuit
- Cleaning refrigerant circuit
- General information about cleaning refrigerant circuit
- Preparations for cleaning refrigerant circuit (flushing with R1234yf refrigerant)
- Refrigerant circuit cleaning procedure
- Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with expansion valve and receiver
- Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with restrictor and receiver (without
- Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (without auxiliary air c
- Principle circuit diagrams for cleaning (flushing circuits) - vehicles with high-voltage system (with auxiliary air cond
- Adapters for setting up flushing circuits
- General information about blowing through with compressed air or nitrogen
- Blowing through refrigerant circuit with compressed air or nitrogen
- Checking pressures with pressure gauge
- Display on pressure gauges
- Pressure gauges enable the following test and measurement work
Working with air conditioner service station20 pages
- Working with air conditioner service station
- Working with air conditioner service station
- Connecting air conditioner service station to refrigerant circuit
- Performing gas analysis of refrigerant
- Exhaust refrigerant circuit.
- Evacuating refrigerant circuit
- Charging the refrigerant circuit
- Bringing air conditioning system into service after charging
- Switching off air conditioner service station and separating from refrigerant circuit
- Charging refrigerant in reservoir
- Emptying air conditioner service station
- Cleaning electrical air conditioning compressor
- Cleaning refrigerant circuit
- Filling contaminated refrigerant in a recycling bottle for analysis, processing or disposal
- Checking pressures
- General information on checking pressures in the refrigerant circuit
- Pressures and temperatures in the refrigerant circuit
- Checking pressures in the refrigerant circuit with the ignition switched off
- Checking pressures with air conditioning system switched on - vehicles with mechanical air conditioning compressor
- Checking pressures with air conditioning system switched on - vehicles with electrical air conditioning compressor
Body