Critical point
- Make
- Volkswagen
- Model
- Tiguan Mk2
- Year
- 2016–2023
- Section
- Technical and physical principles › Critical point
Critical point
Critical point (critical temperature and critical pressure) means the point above which there is no longer a surface of separation between liquid and gas.
Above its critical point, a substance is always gaseous.
At temperatures below the critical point, all types of refrigerant contained within a pressure vessel exhibit a liquid phase and a gas phase. In other words there is a gas cushion above the liquid.
As long as there is gas in the pressure vessel alongside the liquid, the pressure depends directly on the ambient temperature Chapter“Vapour pressure table for refrigerant”.
Note
- Refrigerants used in motor vehicles are not to be mixed together. Only refrigerants specified for the respective air conditioning system may be used.
- The vapour pressures of the two refrigerants R1234yf and R134a are very similar over a broad temperature range, which is why it is impossible to differentiate between the two refrigerants Air conditioning system with R134a refrigerant, General information about air conditioning system. It is only possible to differentiate by means of relevant sensors through which the chemical structure of the refrigerant is analysed Chapter“Analysis of R1234yf refrigerant”.
Parts & tools for this job For 2016 Volkswagen Tiguan
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Tiguan 2016 cabin filter