Workshop Manuals Factory service & repair Volkswagen
01 Fuel supply system - Petrol engines02 Fuel supply system - Diesel engines03 4-Cylinder Common Rail Engine (2.0 l, 4V, Turbocharger)04 4-Cyl. Direct Injection Engine (2.0 l, 4 V, EA 888 Gen III BZ, Turbocharger, Chain Drive)05 Propshaft and rear final drive06 7-speed dual clutch gearbox 0DL07 Brake system08 Running gear, axles, steering09 Wheels and Tyres Guide10 Heating, air conditioning11 Heating and air conditioning: Auxiliary heater12 Air conditioning systems with R1234yf refrigerant - General information13 Electrical: Communication14 Electrical system15 General body repairs, exterior16 General body repairs, interior
Volkswagen Tiguan Mk2 (2016-2023)12 · Air conditioning systems with R1234yf refrigerant - General information
12 · Heating & A/C

Restrictor

Make
Volkswagen
Model
Tiguan Mk2
Year
2016–2023
Section
Refrigerant circuit › Restrictor
Air conditioning systems with R1234yf refrigerant - General informationRestrictor

Restrictor

Restrictor in front of evaporator

Note

  • Currently, there is no air conditioning system with a restrictor installed in front of the evaporator.

  • The restrictor creates a restriction. This restriction limits the flow, separating the high pressure and low pressure sides in the refrigerant circuit. Upstream of the restrictor, the refrigerant is warm due to the high pressure. Downstream of the restrictor, the refrigerant is cold due to the low pressure. Upstream of the narrow point is a strainer to catch dirt and downstream of the narrow point is a strainer to atomise the refrigerant before it enters the evaporator.
  • N87-0337

Note

  • Arrow (A) on the restrictor points to the evaporator.
  • Renew every time the refrigerant circuit is opened.
  • Note different versions; refer to the various customer service information Electronic parts catalogue.

Restrictor in front of heat exchanger for high-voltage battery (chiller)

The restrictor creates a restriction. This restriction limits the flow, separating the high pressure and low pressure sides in the refrigerant circuit. Upstream of the restrictor, the refrigerant is warm due to the high pressure. Downstream of the restrictor, the refrigerant is cold due to the low pressure.

A87-11584

Note

  • The illustration shows a refrigerant line (A) with a permanently installed restrictor (B) (without strainer).
  • The diameter of the shown restrictor hole (B) is approx. 0.7 mm. Depending on the refrigerant line version, this restrictor is permanently installed or it can be removed. For the removable version a strainer may be fitted to prevent the restrictor hole from being blocked by suspended particles.
  • Check for soiling before installing and clean or renew as necessary.
  • Observe different versions.

Parts & tools for this job For 2016 Volkswagen Tiguan