01 Fuel supply system - Petrol engines02 Fuel supply system - Diesel engines03 4-Cylinder Common Rail Engine (2.0 l, 4V, Turbocharger)04 4-Cyl. Direct Injection Engine (2.0 l, 4 V, EA 888 Gen III BZ, Turbocharger, Chain Drive)05 Propshaft and rear final drive06 7-speed dual clutch gearbox 0DL07 Brake system08 Running gear, axles, steering09 Wheels and Tyres Guide10 Heating, air conditioning11 Heating and air conditioning: Auxiliary heater12 Air conditioning systems with R1234yf refrigerant - General information13 Electrical: Communication14 Electrical system15 General body repairs, exterior16 General body repairs, interior
Volkswagen Tiguan Mk2 (2016-2023)12 · Air conditioning systems with R1234yf refrigerant - General information
12 · Heating & A/C

Possible complaints

Make
Volkswagen
Model
Tiguan Mk2
Year
2016–2023
Section
Refrigerant circuit › Possible complaints
Air conditioning systems with R1234yf refrigerant - General informationPossible complaints

Possible complaints

Heating, air conditioning

Note

  • For all complaints marked with a * Chapter“Checking pressures”.
  • If on vehicles with 2 evaporators a problem is encountered in just one evaporator, check the pressures in the refrigerant circuit as well Chapter“Checking pressures”.

  • The cooling has failed completely.*
  • Insufficient cooling output at all vehicle speeds and engine speeds.*
  • No cooling or insufficient cooling after a distance of several kilometres has been driven. *
  • No cooling or insufficient cooling from one or two evaporators (on vehicles with 2nd heater and air conditioner/evaporators). *
  • Actuation of the air conditioner compressor (via the air conditioning system magnetic clutch N25 or the air conditioner compressor regulating valve N280) is switched off by the respective control unit (e.g. the operating and display unit for front air conditioning system E87, the air conditioning system control unit J301 or the Climatronic control unit J255) due to pressure in the refrigerant circuit being too high or too low * Vehicle diagnostic tester in “Guided fault finding” mode - air conditioning system.
  • The electrical air conditioner compressor V470 is not actuated by the control unit for air conditioning compressor J842 due to pressure being too high or too low * Vehicle diagnostic tester in “Guided fault finding” mode - air conditioning system and battery regulation.
  • If fresh air supply is lacking or drops significantly after a few miles (evaporator iced up) *Vehicle diagnostic tester in “Guided fault finding” mode - air conditioning system.

In addition the following complaints may also arise:

The air conditioner compressor is noisy.

Re-tighten the securing bolts for the air conditioner compressor and the air conditioner compressor bracket using a torque wrench Heating, air conditioningRep. gr.87Refrigerant circuit; System overview - refrigerant circuit.

Check the routing of the refrigerant lines. These must not rest against other components and must not be under any strain (realign them if necessary) Heating, air conditioningRep. gr.87Refrigerant circuit; System overview - refrigerant circuit.

Noises (refrigerant hammering) occur immediately after the air conditioning is switched on and/or in a curve or when the brakes are applied:

Drain the refrigerant circuit, evacuate it and recharge (too much refrigerant or refrigerant oil in the circuit) → Chapter and Chapter“Checking pressures”.

Note

  • Excess refrigerant oil in the circuit may also cause this problem (e.g. if the refrigerant oil level was not checked after the air conditioner compressor was renewed) → Chapter.

Water sprays out of the air vents (dash panel or footwell) although the air conditioning system otherwise works properly:

Check condensation drain to ensure that it is routed correctly. It should not be kinked or crushed Heating, air conditioningRep. gr.87Front heater and air conditioner.

The condensed water drain valve must not be hindered in its operation by wax or underbody sealant and must open and close properly Heating, air conditioningRep. gr.87Front heater and air conditioner.

Check plenum chamber cover. It must not be damaged and must be installed correctly (no water should run into the evaporator) Heating, air conditioningRep. gr.87Overview of fitting locations - air conditioning system; Overview of fitting locations - components outside passenger compartment.

Check water drainage points of plenum chamber. These should not be blocked (e.g. by leaves) Heating, air conditioningRep. gr.87Overview of fitting locations - air conditioning system; Overview of fitting locations - components outside passenger compartment.

Note

  • Installation location and other information about these components Heating, air conditioningRep. gr.87Overview of fitting locations - air conditioning system.

Parts & tools for this job For 2016 Volkswagen Tiguan