Refrigerant circuit cleaning procedure
- Make
- Volkswagen
- Model
- Tiguan Mk2
- Year
- 2016–2023
- Section
- Refrigerant circuit › Refrigerant circuit cleaning procedure
‹ Prev Preparations for cleaning refrigerant circuit (flushing with R1234yf refrigerant)Next › Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with expansion valve and receiver
Air conditioning systems with R1234yf refrigerant - General informationRefrigerant circuit cleaning procedure
Refrigerant circuit cleaning procedure
Note
- The procedure runs automatically as per the program in the air conditioner service stationOperating instructions air conditioner service station.
- After switching on, the flushing circuit (refrigerant circuit with connecting hoses and flushing device for refrigerant circuits) is evacuated first and, in the process, the refrigerant circuit is checked for leaks (it may be necessary to proceed to the next step manually depending on the version of air conditioning service station).
- Once the refrigerant circuit has been checked for leaks by means of evacuating, a certain amount of refrigerant is filled in the system to check the flushing/refrigerant circuit for correct assembly (pressure test).
- After the pressure check, the refrigerant is extracted, the refrigerant circuit is evacuated again, if necessary, and the cleaning (flushing) process begins.
- A predefined volume of refrigerant is charged in the refrigerant circuit via the high pressure side of the air conditioner service station (in the opposite direction of normal flow during air conditioning system operation and therefore on the low pressure side of the vehicle's refrigerant circuit). Alternatively, refrigerant is charged continually (depending on the internal volume of the flushing circuit e.g. 3 kg) until the refrigerant circuit and the inspection windows of the flushing device for refrigerant circuits are completely full with liquid refrigerant (the system detects, e.g. over a certain period of time, when refrigerant ceases to flow depending on the version of air conditioner service station).
- Once the predetermined amount of refrigerant has been filled in the system, the heater, for example, of the flushing device for refrigerant circuits is switched on depending on the type of air conditioner service station and flushing device for refrigerant circuits (only if the refrigerant is extracted in gaseous form out of the flushing device for refrigerant circuits).
- When the refrigerant has been extracted, the heater of the flushing device for refrigerant circuits is switched off (if fitted), the refrigerant circuit may have to be evacuated briefly again depending on the type, and following evacuation the refrigerant oil evacuated by the air conditioner service station out of the refrigerant circuit is separated of water.
- The procedure for charging with refrigerant, extracting (and evacuating) is carried out three times (that means a total of four times).
- After extracting for the fourth time, the flushing circuit is evacuated depending on the type of air conditioner service station.
‹ Prev Preparations for cleaning refrigerant circuit (flushing with R1234yf refrigerant)Next › Principle circuit diagrams for cleaning (flushing circuits) - refrigerant circuit with expansion valve and receiver
Parts & tools for this job For 2016 Volkswagen Tiguan
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Tiguan 2016 cabin filter