01 Fuel supply system - Petrol engines02 Fuel supply system - Diesel engines03 4-Cylinder Common Rail Engine (2.0 l, 4V, Turbocharger)04 4-Cyl. Direct Injection Engine (2.0 l, 4 V, EA 888 Gen III BZ, Turbocharger, Chain Drive)05 Propshaft and rear final drive06 7-speed dual clutch gearbox 0DL07 Brake system08 Running gear, axles, steering09 Wheels and Tyres Guide10 Heating, air conditioning11 Heating and air conditioning: Auxiliary heater12 Air conditioning systems with R1234yf refrigerant - General information13 Electrical: Communication14 Electrical system15 General body repairs, exterior16 General body repairs, interior
Volkswagen Tiguan Mk2 (2016-2023)12 · Air conditioning systems with R1234yf refrigerant - General information
12 · Heating & A/C

Refrigerant circuit cleaning procedure

Make
Volkswagen
Model
Tiguan Mk2
Year
2016–2023
Section
Refrigerant circuit › Refrigerant circuit cleaning procedure
Air conditioning systems with R1234yf refrigerant - General informationRefrigerant circuit cleaning procedure

Refrigerant circuit cleaning procedure

Note

  • The procedure runs automatically as per the program in the air conditioner service stationOperating instructions air conditioner service station.

  • After switching on, the flushing circuit (refrigerant circuit with connecting hoses and flushing device for refrigerant circuits) is evacuated first and, in the process, the refrigerant circuit is checked for leaks (it may be necessary to proceed to the next step manually depending on the version of air conditioning service station).
  • Once the refrigerant circuit has been checked for leaks by means of evacuating, a certain amount of refrigerant is filled in the system to check the flushing/refrigerant circuit for correct assembly (pressure test).
  • After the pressure check, the refrigerant is extracted, the refrigerant circuit is evacuated again, if necessary, and the cleaning (flushing) process begins.
  • A predefined volume of refrigerant is charged in the refrigerant circuit via the high pressure side of the air conditioner service station (in the opposite direction of normal flow during air conditioning system operation and therefore on the low pressure side of the vehicle's refrigerant circuit). Alternatively, refrigerant is charged continually (depending on the internal volume of the flushing circuit e.g. 3 kg) until the refrigerant circuit and the inspection windows of the flushing device for refrigerant circuits are completely full with liquid refrigerant (the system detects, e.g. over a certain period of time, when refrigerant ceases to flow depending on the version of air conditioner service station).
  • Once the predetermined amount of refrigerant has been filled in the system, the heater, for example, of the flushing device for refrigerant circuits is switched on depending on the type of air conditioner service station and flushing device for refrigerant circuits (only if the refrigerant is extracted in gaseous form out of the flushing device for refrigerant circuits).
  • When the refrigerant has been extracted, the heater of the flushing device for refrigerant circuits is switched off (if fitted), the refrigerant circuit may have to be evacuated briefly again depending on the type, and following evacuation the refrigerant oil evacuated by the air conditioner service station out of the refrigerant circuit is separated of water.
  • The procedure for charging with refrigerant, extracting (and evacuating) is carried out three times (that means a total of four times).
  • After extracting for the fourth time, the flushing circuit is evacuated depending on the type of air conditioner service station.

Parts & tools for this job For 2016 Volkswagen Tiguan