01 6-cylinder direct-injection engine (3.0 l engine, 4V, hybrid)02 8-cylinder diesel engine (4.2 l engine, common rail)03 6-cylinder diesel engine (3.0 l engine, common rail)04 6-cylinder direct-injection engine (3.6 l engine, 4V)05 6-cylinder direct-injection engine (3.0 l engine, 4V, supercharger)06 8-cyl. direct injection engine (4.2 l 4V engine)07 Fuel supply system - Diesel engines08 6-cylinder diesel engine (3.0 l engine, common rail, generation II)09 8-speed automatic gearbox 0C810 Transfer box and final drive11 Wheels and Tyres Guide - Standard12 Brake systems13 Running gear, axles, steering14 Wheels and Tyres Guide15 Heating, air conditioning16 Heating and air conditioning: Auxiliary heater17 Electrical system18 Hybrid electrical system19 Electrical: Communication20 General body repairs, interior21 General body repairs, exterior22 Vehicle-specific paint information
Volkswagen Touareg Mk2 (2010-2018)15 · Heating, air conditioning
15 · Heating & A/C

Removing and installing condenser

Make
Volkswagen
Model
Touareg Mk2
Year
2010–2018
Section
Refrigerant circuit › Removing and installing condenser
Heating, air conditioningRemoving and installing condenser

Removing and installing condenser

Power unit

Special tools and workshop equipment requiredTorque wrench V.A.G 1331/ (5…50 Nm)
W00-11166
Air conditioner service station

Note

  • The refrigerant must be extracted beforehand, with the air conditioning service station.
  • The previously used air conditioner service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
  • To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
  • Releasing refrigerant into the environment is a criminal offence.
  • Observe safety precautions Chapter“Safety measures for when working on vehicles with a start-stop system”.

First carry out the following work:

Switch off all electrical consumers.

Switch off ignition.

Remove ignition key.

Removing

Observe safety precautions when working on the high-voltage system Chapter“Safety precautions when working on high-voltage system”.

Observe safety precautions when working in the vicinity of high-voltage components Chapter“Safety precautions when working in the vicinity of high-voltage components”.

Observe risk category of high-voltage system Rep. gr.93General warning instructions for work on the high-voltage system.

Comply with notes Chapter“Working on refrigerant circuit”.

Extract refrigerant with air conditioning service station. Comply with notes → Chapter.

Additional work for hybrid vehicles:

Observe risk category of high-voltage system Rep. gr.93General warning instructions for work on the high-voltage system.

Detach coolant expansion tank and lay it aside Power unitRep. gr.19Cooling system: Cooling system - locations.

Continuation for all vehicles

Remove number plate holder (2) and centre ventilation grille (3)General body repairs, exteriorRep. gr.63Front bumper cover; Front bumper cover with attachments.

N19-10513

Fold back air guide on left and right of air guide aperture (arrow) and remove bolts (A) (25 Nm) located underneath.

N19-10545

Press radiator module into engine compartment and release and pull out clips (arrows) of air guide on top of radiator.

N19-10548

Release locking pins (B) of both upper radiator mountings (A), by pressing in (direction of arrow), and pull out upwards.

N19-10549

Carefully push radiator module in direction of engine room and secure using suitable means.

Evacuate refrigerant circuit using air conditioner service station before opening refrigerant circuit.

Depending on engine, observe additional cooler in front of condenser Power unitRep. gr.19Cooling system; Cooling system - fitting locations.

CAUTIONRisk of freezing injury caused by escaping pressurised refrigerant.There is a risk of injury to the skin and parts of the body due to freezing.Always wear safety gloves.Always wear safety goggles.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If more than 10 minutes passed since the refrigerant has been extracted, do not open the refrigerant circuit prior to extracting refrigerant anew. Due to re-evaporation, pressure will be built up in the refrigerant circuit.
N87-0860
  • Clip
  • O-ring
    Renew
    23.8 mm; 2.4 mm
  • O-ring
    Renew
    9.5 mm; 2.5 mm
  • Bolts
    12 ± 1.5 Nm
    Refrigerant line
  • Condenser

Loosen bolts securing refrigerant lines (4).

Release clip of cooler bracket (1).

Remove condenser upwards out of lock carrier.

Installing

Install in reverse order.