Workshop Manuals Factory service & repair Volkswagen
01 6-cylinder direct-injection engine (3.0 l engine, 4V, hybrid)02 8-cylinder diesel engine (4.2 l engine, common rail)03 6-cylinder diesel engine (3.0 l engine, common rail)04 6-cylinder direct-injection engine (3.6 l engine, 4V)05 6-cylinder direct-injection engine (3.0 l engine, 4V, supercharger)06 8-cyl. direct injection engine (4.2 l 4V engine)07 Fuel supply system - Diesel engines08 6-cylinder diesel engine (3.0 l engine, common rail, generation II)09 8-speed automatic gearbox 0C810 Transfer box and final drive11 Wheels and Tyres Guide - Standard12 Brake systems13 Running gear, axles, steering14 Wheels and Tyres Guide15 Heating, air conditioning16 Heating and air conditioning: Auxiliary heater17 Electrical system18 Hybrid electrical system19 Electrical: Communication20 General body repairs, interior21 General body repairs, exterior22 Vehicle-specific paint information
Volkswagen Touareg Mk2 (2010-2018)15 · Heating, air conditioning
15 · Heating & A/C

Removing and installing front expansion valve

Make
Volkswagen
Model
Touareg Mk2
Year
2010–2018
Section
Refrigerant circuit › Removing and installing front expansion valve
Heating, air conditioningRemoving and installing front expansion valve

Removing and installing front expansion valve

Special tools and workshop equipment requiredTorque wrench V.A.G 1331/ (5…50 Nm)
W00-11166
Air conditioner service station

Removing

Observe safety precautions when working on the high-voltage system Chapter“Safety precautions when working on high-voltage system”.

Observe safety precautions when working in the vicinity of high-voltage components Chapter“Safety precautions when working in the vicinity of high-voltage components”.

Observe risk category of high-voltage system Rep. gr.93General warning instructions for work on the high-voltage system.

Comply with notes Chapter“Working on refrigerant circuit”.

Extract refrigerant with air conditioning service station. Comply with notes → Chapter.

Remove plenum chamber cover Rep. gr.64.

Hybrid vehicles

Observe risk category of high-voltage system Rep. gr.93General warning instructions for work on the high-voltage system.

Continuation for all vehicles

CAUTIONRisk of freezing injury caused by escaping pressurised refrigerant.There is a risk of injury to the skin and parts of the body due to freezing.Always wear safety gloves.Always wear safety goggles.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If more than 10 minutes passed since the refrigerant has been extracted, do not open the refrigerant circuit prior to extracting refrigerant anew. Due to re-evaporation, pressure will be built up in the refrigerant circuit.

Unscrew bolts (1) (10 ± 1 Nm) and pull out refrigerant lines from expansion valve.

N87-0839

Unscrew bolts (1) from expansion valve (2) and remove expansion valve.

Take care not to damage retaining plate (3).

N87-0863
Bolts (10 ± 1 Nm)Expansion valveRetaining plateO-ring 14.3 mm; 2.4 mmO-ring 10.8 mm; 1.82 mm

Installing

Installation is carried out in the reverse order. When installing, note the following:

Renew O-rings (4) and (5) and refrigerant pipes.

Torque setting for bolts is 10 ± 1 Nm.

Parts & tools for this job For 2010 Volkswagen Touareg