Checking:
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary air heaters -B2L/D2L- › Checking:
Checking:
Special tools and workshop equipment requiredHand multimeter V.A.G 1526B

Not illustrated
- Commercially available measuring glass (0 ml to 25 ml)
Set measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect test probes included in auxiliary measuring set V.A.G 1594C to contacts 3 (-) and 4 (+) of heater control unit J65.
Disconnect connector on glow spark plug Q5.
Place fuel line in measuring glass (10 ml - 25 ml).
Switch heater on.
Bleed fuel hose.
Switch heater off and empty measuring glass.
Switch heater on again.
As soon as fuel is delivered start stop watch.
Read off voltage value on hand multimeter V.A.G 1526B.
Switch heater off after one minute.
Read off fuel delivered and compare measured values with diagram. Fuel delivery is OK when the measured values lie within the hatched area of the diagram.