Checking
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary air heaters -B2L/D2L- › Checking
Checking
Special tools and workshop equipment requiredVoltage tester V.A.G 1527B
Not illustrated
- Current flow diagram
- Cold spray (commercially available)
Switching values for heater overheating switch F17
- Opens at temperatures above 110°C
- Closes at temperatures below 99°C
Connect voltage tester V.A.G 1527B between auxiliary heater fuse S62 and contact -5- on heater control unit J65.
Voltage tester V.A.G 1527B lights up:
Check for line interruption according to Current flow diagrams, Electrical fault finding and Fitting locations, renew heater control unit J65 if necessary.
Voltage tester V.A.G 1527B does not light up:
Renew heater overheating switch F17.
Special tools and workshop equipment requiredHand multimeter V.A.G 1526B

Not illustrated
- Current flow diagram
- Cold spray (commercially available)
Switching values for heater overheating switch F17
- Opens at temperatures above 110°C
- Closes at temperatures below 99°C
Remove heater overheating switch F17.
Measure resistance between contacts on heater overheating switch F17.
Note
- Temperature of heater overheating switch F17 must be below 99°C.
Resistance = > 1Ω
Heat up heater overheating switch F17 using heat gun VAS 5179 (to at least 110°C).
Resistance = ∞Ω
If one of these resistance values is not achieved, renew heater overheating switch F17.
Parts & tools for this job For 1990 Volkswagen Transporter
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Transporter 1990 cabin filter
As an Amazon Associate we earn from qualifying purchases.