Checking:
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary air heaters B3LP/D3LP/B3LC/D3LC › Checking:
Checking:
Set measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect test probes to contacts -T4a/4- (positive) and -T4a/3- (negative) of heater control unit J65.
Warning Fuel system is under pressure! Before opening system, wrap a cloth around the connection. Then release pressure by carefully loosening the connection.
Disconnect fuel line at heater unit and insert it in the measuring glass.
Switch heater on.
Fuel delivery begins approx. 45 seconds after switching on.
Switch heater off as soon as fuel flows into the measuring glass from the fuel line and wait for run-on period to end.
Empty measuring glass and place fuel line in measuring glass.
Switch heater on again.
Fuel delivery begins approx. 45 seconds after switching on.
Read off voltage value on hand multimeter V.A.G 1526B.
Fuel supply is switched off automatically after 90 seconds.
Switch heater off and compare quantity of fuel delivered (in measuring glass) with the values in the table.
| Heater type | Quantity of fuel delivered in ml |
|---|---|
| B3LC / B3LC compact | 9 to 10 |
| D3LC / D3LC compact | 8 to 9 |
| B3LP / B3LP compact | 8 to 9 |
| D3LP / D3LP compact | 7 to 8 |
Fuel delivery is ok when the quantity of fuel in the measuring glass corresponds with the values in the table.
If the quantity of fuel delivered does not correspond with the values in the table:
Renew fuel pump G23.