Fault table
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary air heaters B3LP/D3LP/B3LC/D3LC › Fault table
‹ Prev Removing operating and display unit for camping equipment E153Next › Erasing fault memory using basic unit VAS 5019/1
Supplementary heatingFault table
Fault table
Note
- The following table lists all the faults, with the corresponding 3-digit code numbers, that can be detected by heater control unit J65 and displayed on basic unit VAS 5019/1.
- The fault code number is displayed alphanumerically on the display on operating and display unit for camping equipment E153. Example: “F30” corresponds to “030”, “F60” corresponds to “060”.
- Heater control unit J65 detects up to five faults, which are stored one after the other in the fault memory. If the same fault occurs several times, then it can appear up to five times in the fault memory.
- The fault table can also include the type of fault.
- After the repair, the heating must undergo a function test and the fault memory interrogated again using basic unit VAS 5019/1.
- If other faults are displayed after interrogating the fault memory again, then they must be rectified according to the fault table.
- If the voltage supply was interrupted at heater control unit J65 or the terminal voltage less than 10.5 V, all segments flash on pre-selection clock with temperature regulator E187. In this case, all pre-selected times which have been set are erased.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 000 | ||
| No fault detectedNote | If “No fault detected” appears after performing repairs, the self-diagnosis is ended. | |
| 001 | ||
| Warning - overvoltageNote | ||
| Alternator defective. | Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations | |
| Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective. | Check battery charger. |
Display on operating and display unit for camping equipment E153
: normal display.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 002 | ||
| Warning - undervoltageNote | Second battery flat. | Check second battery. |
| Wiring and/or connectors to heater control unit J65 defective. | Check wiring and/or connectors using current flow diagram. | |
| Alternator defective. | Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations | |
| Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective. | Check battery charger. |
Display on operating and display unit for camping equipment E153
: normal display.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 010 | ||
| Overvoltage shutdown | ||
| Alternator defective. | Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations | |
| Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective. | Check battery charger. | |
| 011 | ||
| Undervoltage shutdownNote | ||
| Second battery flat. | Check second battery. | |
| Wiring and/or connectors to heater control unit J65 defective. | Check wiring and/or connectors using current flow diagram. | |
| Alternator defective. | Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations | |
| Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective. | Check battery charger. |
Display on operating and display unit for camping equipment E153
: normal display.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 012 | ||
| OverheatingNote | ||
| Shutdown after 3x overheating | Intake and/or outlet duct blocked | Carry out visual check. |
| Wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17 defective. | Check wiring and/or connectors using current flow diagram. | |
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Heater overheating switch F17 defective. | Check heater overheating switch F17, renew if necessary → Chapter. |
Note heater control unit J65
can only be erased by
basic unit VAS 5019/1.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 013 | ||
| Overheating | ||
| Shutdown by flame monitor G64Note | Heater overheating switch F17 defective. | Check heater overheating switch F17, renew if necessary → Chapter.Check outer covers and heat exchanger for deformation. |
| 020 | ||
| Glow plug for heater Q9 | ||
| Interruption | Interruption in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372. | Check wiring and/or connectors using current flow diagram. |
| Glow plug for heater Q9 defective. | Check glow plug for heater Q9Chapter. | |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. |
Note flame monitor G64
and not by
heater overheating switch F17.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 023 | ||
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 | ||
| Interruption | Interruption in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372. | Check wiring and/or connectors Current flow diagrams, Electrical fault finding and Fitting locations. |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| 023 | ||
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 | ||
| Short circuit | Short circuit in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372. | Check wiring and/or connectors using current flow diagram. |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| 025 | ||
| Diagnosis lead | ||
| Short circuit | Short circuit in diagnosis lead from heater control unit J65 to operating and display unit for camping equipment E153 or to heating/temperature/time control switch E13 (▸12.95) or to pre-selection clock with temperature regulator E187 (01.96▸). | Check wiring and/or connectors using current flow diagram. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 029 | ||
| 030 | ||
| 031 | ||
| 032 | ||
| 033 | ||
| Combustion, fresh and heated air blower V81 | ||
| Does not rotate | Wiring and/or connectors from printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 to combustion, fresh and heated air blower V81 defective. | Check wiring and/or connectors using current flow diagram. |
| Combustion, fresh and heated air blower V81 defective. | Renew combustion, fresh and heated air blower V81Chapter. | |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 036 | ||
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 | ||
| Short circuit | Short circuit in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372. | Check wiring and/or connectors using current flow diagram. |
| Combustion, fresh and heated air blower V81 defective. | Renew combustion, fresh and heated air blower V81Chapter. | |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| 047 | ||
| Fuel pump G23 | ||
| Short circuit | Short circuit in wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17. | Check wiring and/or connectors using current flow diagram. |
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Heater overheating switch F17 defective. | Check heater overheating switch F17, renew if necessary → Chapter. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 050 | ||
| Too many attempts to startNote | ||
| Exhaust gas pipe and combustion air supply obstructed. | Check exhaust gas pipe and combustion air supply, clean if necessary, e.g. blow out with compressed air. | |
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Glow plug for heater Q9 defective. | Check glow plug for heater Q9Chapter. |
Note heater control unit J65
can only be erased by
basic unit VAS 5019/1.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 052 | ||
| Safety time exceededNoteno flame | ||
| Exhaust gas pipe and combustion air supply obstructed. | Check exhaust gas pipe and combustion air supply, clean if necessary, e.g. blow out with compressed air. | |
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17 defective. | Check wiring and/or connectors using current flow diagram. | |
| Glow plug for heater Q9 defective. | Check glow plug for heater Q9Chapter. |
Note
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 053 | ||
| Flame failure in “START PHASE” | ||
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| 054 | ||
| Flame failure in “HIGH” stage | ||
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 055 | ||
| Flame failure in “MEDIUM” stage | ||
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| 056 | ||
| Flame failure in “LOW” stage | ||
| Quantity of fuel delivered not ok. | Check fuel lines for damage. | |
| Check quantity of fuel delivered → Chapter. | ||
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 060 | ||
| Temperature sensor G18 | ||
| Interruption | Vehicles without camping equipment: | |
| Interruption in wiring and/or connectors to heater control unit J65 via temperature sensor G18 | Check wiring and/or connectors using current flow diagram. | |
| Temperature sensor G18 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| Interruption | Vehicles with camping equipment: | |
| Interruption in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153. | Check wiring and/or connectors using current flow diagram. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 061 | ||
| Temperature sensor G18 | ||
| Short circuit | Vehicles without camping equipment: | |
| Short circuit in wiring and/or connectors to heater control unit J65 via temperature sensor G18 | Check wiring and/or connectors using current flow diagram. | |
| Temperature sensor G18 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. | |
| Short circuit | Vehicles with camping equipment: | |
| Short circuit in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153 | Check wiring and/or connectors using current flow diagram. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 062 | ||
| Control panel | ||
| Interruption | Vehicles without camping equipment: | |
| Interruption in wiring and/or connectors to heater control unit J65 via heating/temperature/time control switch E13 (▸12.95) or via pre-selection clock with temperature regulator E187 (01.96▸). | Check wiring and/or connectors using current flow diagram. | |
| Heating/temperature/time control switch E13 (▸12.95) defective. | Check heating/temperature/time control switch E13, renew if necessary → Chapter. | |
| Pre-selection clock with temperature regulator E187 (01.96▸) defective. | Check pre-selection clock with temperature regulator E187, renew if necessary. | |
| Interruption | Vehicles with camping equipment: | |
| Interruption in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153. | Check wiring and/or connectors using current flow diagram. | |
| Operating and display unit for camping equipment E153 defective. | Check operating and display unit for camping equipment E153, renew if necessary Rep. Gr.76. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 063 | ||
| Control panel | ||
| Short circuit | Vehicles without camping equipment: | |
| Short circuit in wiring and/or connectors to heater control unit J65 via heating/temperature/time control switch E13 (▸12.95) or via pre-selection clock with temperature regulator E187 (01.96▸). | Check wiring and/or connectors using current flow diagram. | |
| Heating/temperature/time control switch E13 (▸12.95) defective. | Check heating/temperature/time control switch E13, renew if necessary → Chapter. | |
| Pre-selection clock with temperature regulator E187 (01.96▸) defective. | Check pre-selection clock with temperature regulator E187, renew if necessary. | |
| Short circuit | Vehicles with camping equipment: | |
| Short circuit in wiring and/or connectors to heater control unit J65S via operating and display unit for camping equipment E153. | Check wiring and/or connectors using current flow diagram. | |
| Operating and display unit for camping equipment E153 defective. | Check operating and display unit for camping equipment E153, renew if necessary Rep. Gr.76. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 064 | ||
| Flame monitor G64 | ||
| Interruption | Interruption in wiring and/or connectors to heater control unit J65 via printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and flame monitor G64. | Check wiring and/or connectors using current flow diagram. |
| Flame monitor G64 defective | Check flame monitor G64, renew if necessary → Chapter. | |
| 065 | ||
| Flame monitor G64 | ||
| Short circuit | Short circuit in wiring and/or connectors to heater control unit J65 via printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and flame monitor G64. | Check wiring and/or connectors using current flow diagram. |
| Flame monitor G64 defective | Check flame monitor G64, renew if necessary → Chapter. | |
| Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective. | Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter. |
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 070Note | ||
| Temperature sensor G18 | ||
| Interruption | Interruption in wiring and/or connectors from operating and display unit for camping equipment E153 via temperature sensor G18. | Check wiring and/or connectors using current flow diagram. |
| Temperature sensor G18 defective. | Check temperature sensor G18, renew if necessary → Chapter. | |
| 090 | ||
| Heater control unit J65 | ||
| defective | Wiring and/or connectors to heater control unit J65 defective. | Check wiring and/or connectors using current flow diagram. |
| Heater control unit J65 defective. | Renew heater control unit J65Chapter. |
Only displayed on operating and display unit for camping equipment E153
.
| Fault code number and meaning | Possible cause of fault | Rectifying fault |
|---|---|---|
| 091 | ||
| Heater control unit J65 | ||
| External interference voltage | Interference voltage at heater control unit J65 from onboard power supply. Possible causes: Interference caused by car telephone.Short-distance interference suppressor for windscreen wiper motor, coolant fan or rear window wiper motor defective. | Localise and rectify fault.After eliminating the interference voltage, interrogate the fault memory again. |
| 092 | ||
| 093 | ||
| 094 | ||
| Heater control unit J65 | ||
| defective | Wiring and/or connectors to heater control unit J65 defective. | Check wiring and/or connectors using current flow diagram. |
| Heater control unit J65 defective. | Renew heater control unit J65Chapter. |
‹ Prev Removing operating and display unit for camping equipment E153Next › Erasing fault memory using basic unit VAS 5019/1
Parts & tools for this job For 1990 Volkswagen Transporter
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Transporter 1990 cabin filter
As an Amazon Associate we earn from qualifying purchases.