01 5-cylinder diesel engine (distributor-type injection pump)02 5-speed manual gearbox 02G, four-wheel drive03 Self-diagnosis for automatic gearbox 01P - from 01.9504 Automatic gearbox 01P - after 01.9505 Running gear: Guide for using trailers06 Wheels and Tyres Guide - General Information07 Running gear: Guide for increasing and decreasing load ratings08 Wheels and Tyres Guide09 Brake systems as of January 199610 Running gear, axles, steering11 Electrical system self-diagnosis12 Electrical system13 Electrical: Communication14 General body repairs, exterior15 General body repairs, interior16 Supplementary heating
Volkswagen Transporter T4 (1990-2003)16 · Supplementary heating
16 · Heating & A/C

Fault table

Make
Volkswagen
Model
Transporter T4
Year
1990–2003
Section
Auxiliary air heaters B3LP/D3LP/B3LC/D3LC › Fault table
Supplementary heatingFault table

Fault table

Note

  • The following table lists all the faults, with the corresponding 3-digit code numbers, that can be detected by heater control unit J65 and displayed on basic unit VAS 5019/1.
  • The fault code number is displayed alphanumerically on the display on operating and display unit for camping equipment E153. Example: “F30” corresponds to “030”, “F60” corresponds to “060”.
  • Heater control unit J65 detects up to five faults, which are stored one after the other in the fault memory. If the same fault occurs several times, then it can appear up to five times in the fault memory.

  • The fault table can also include the type of fault.
  • After the repair, the heating must undergo a function test and the fault memory interrogated again using basic unit VAS 5019/1.
  • If other faults are displayed after interrogating the fault memory again, then they must be rectified according to the fault table.
  • If the voltage supply was interrupted at heater control unit J65 or the terminal voltage less than 10.5 V, all segments flash on pre-selection clock with temperature regulator E187. In this case, all pre-selected times which have been set are erased.
Fault code number and meaningPossible cause of faultRectifying fault
000
No fault detectedNoteIf “No fault detected” appears after performing repairs, the self-diagnosis is ended.
001
Warning - overvoltageNote
Alternator defective.Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations
Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective.Check battery charger.

Display on operating and display unit for camping equipment E153

: normal display.

Fault code number and meaningPossible cause of faultRectifying fault
002
Warning - undervoltageNoteSecond battery flat.Check second battery.
Wiring and/or connectors to heater control unit J65 defective.Check wiring and/or connectors using current flow diagram.
Alternator defective.Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations
Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective.Check battery charger.

Display on operating and display unit for camping equipment E153

: normal display.

Fault code number and meaningPossible cause of faultRectifying fault
010
Overvoltage shutdown
Alternator defective.Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations
Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective.Check battery charger.
011
Undervoltage shutdownNote
Second battery flat.Check second battery.
Wiring and/or connectors to heater control unit J65 defective.Check wiring and/or connectors using current flow diagram.
Alternator defective.Check alternator: Current flow diagrams, Electrical fault finding and Fitting locations
Only for vehicles with camping equipment: 220V, 110V, 12V battery charger A10 defective.Check battery charger.

Display on operating and display unit for camping equipment E153

: normal display.

Fault code number and meaningPossible cause of faultRectifying fault
012
OverheatingNote
Shutdown after 3x overheatingIntake and/or outlet duct blockedCarry out visual check.
Wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17 defective.Check wiring and/or connectors using current flow diagram.
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Heater overheating switch F17 defective.Check heater overheating switch F17, renew if necessary → Chapter.

Note heater control unit J65

can only be erased by

basic unit VAS 5019/1

.

Fault code number and meaningPossible cause of faultRectifying fault
013
Overheating
Shutdown by flame monitor G64NoteHeater overheating switch F17 defective.Check heater overheating switch F17, renew if necessary → Chapter.Check outer covers and heat exchanger for deformation.
020
Glow plug for heater Q9
InterruptionInterruption in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372.Check wiring and/or connectors using current flow diagram.
Glow plug for heater Q9 defective.Check glow plug for heater Q9Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.

Note flame monitor G64

and not by

heater overheating switch F17

.

Fault code number and meaningPossible cause of faultRectifying fault
023
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372
InterruptionInterruption in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372.Check wiring and/or connectors Current flow diagrams, Electrical fault finding and Fitting locations.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
023
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372
Short circuitShort circuit in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372.Check wiring and/or connectors using current flow diagram.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
025
Diagnosis lead
Short circuitShort circuit in diagnosis lead from heater control unit J65 to operating and display unit for camping equipment E153 or to heating/temperature/time control switch E13 (▸12.95) or to pre-selection clock with temperature regulator E187 (01.96▸).Check wiring and/or connectors using current flow diagram.
Fault code number and meaningPossible cause of faultRectifying fault
029
030
031
032
033
Combustion, fresh and heated air blower V81
Does not rotateWiring and/or connectors from printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 to combustion, fresh and heated air blower V81 defective.Check wiring and/or connectors using current flow diagram.
Combustion, fresh and heated air blower V81 defective.Renew combustion, fresh and heated air blower V81Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
Fault code number and meaningPossible cause of faultRectifying fault
036
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372
Short circuitShort circuit in wiring and/or connectors from heater control unit J65 to printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372.Check wiring and/or connectors using current flow diagram.
Combustion, fresh and heated air blower V81 defective.Renew combustion, fresh and heated air blower V81Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
047
Fuel pump G23
Short circuitShort circuit in wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17.Check wiring and/or connectors using current flow diagram.
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Heater overheating switch F17 defective.Check heater overheating switch F17, renew if necessary → Chapter.
Fault code number and meaningPossible cause of faultRectifying fault
050
Too many attempts to startNote
Exhaust gas pipe and combustion air supply obstructed.Check exhaust gas pipe and combustion air supply, clean if necessary, e.g. blow out with compressed air.
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Glow plug for heater Q9 defective.Check glow plug for heater Q9Chapter.

Note heater control unit J65

can only be erased by

basic unit VAS 5019/1

.

Fault code number and meaningPossible cause of faultRectifying fault
052
Safety time exceededNoteno flame
Exhaust gas pipe and combustion air supply obstructed.Check exhaust gas pipe and combustion air supply, clean if necessary, e.g. blow out with compressed air.
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Wiring and/or connectors to heater control unit J65 via fuel pump G23, printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and heater overheating switch F17 defective.Check wiring and/or connectors using current flow diagram.
Glow plug for heater Q9 defective.Check glow plug for heater Q9Chapter.

Note

Fault code number and meaningPossible cause of faultRectifying fault
053
Flame failure in “START PHASE”
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
054
Flame failure in “HIGH” stage
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Fault code number and meaningPossible cause of faultRectifying fault
055
Flame failure in “MEDIUM” stage
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
056
Flame failure in “LOW” stage
Quantity of fuel delivered not ok.Check fuel lines for damage.
Check quantity of fuel delivered → Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
Fault code number and meaningPossible cause of faultRectifying fault
060
Temperature sensor G18
InterruptionVehicles without camping equipment:
Interruption in wiring and/or connectors to heater control unit J65 via temperature sensor G18Check wiring and/or connectors using current flow diagram.
Temperature sensor G18 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
InterruptionVehicles with camping equipment:
Interruption in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153.Check wiring and/or connectors using current flow diagram.
Fault code number and meaningPossible cause of faultRectifying fault
061
Temperature sensor G18
Short circuitVehicles without camping equipment:
Short circuit in wiring and/or connectors to heater control unit J65 via temperature sensor G18Check wiring and/or connectors using current flow diagram.
Temperature sensor G18 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
Short circuitVehicles with camping equipment:
Short circuit in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153Check wiring and/or connectors using current flow diagram.
Fault code number and meaningPossible cause of faultRectifying fault
062
Control panel
InterruptionVehicles without camping equipment:
Interruption in wiring and/or connectors to heater control unit J65 via heating/temperature/time control switch E13 (▸12.95) or via pre-selection clock with temperature regulator E187 (01.96▸).Check wiring and/or connectors using current flow diagram.
Heating/temperature/time control switch E13 (▸12.95) defective.Check heating/temperature/time control switch E13, renew if necessary → Chapter.
Pre-selection clock with temperature regulator E187 (01.96▸) defective.Check pre-selection clock with temperature regulator E187, renew if necessary.
InterruptionVehicles with camping equipment:
Interruption in wiring and/or connectors from heater control unit J65 to operating and display unit for camping equipment E153.Check wiring and/or connectors using current flow diagram.
Operating and display unit for camping equipment E153 defective.Check operating and display unit for camping equipment E153, renew if necessary Rep. Gr.76.
Fault code number and meaningPossible cause of faultRectifying fault
063
Control panel
Short circuitVehicles without camping equipment:
Short circuit in wiring and/or connectors to heater control unit J65 via heating/temperature/time control switch E13 (▸12.95) or via pre-selection clock with temperature regulator E187 (01.96▸).Check wiring and/or connectors using current flow diagram.
Heating/temperature/time control switch E13 (▸12.95) defective.Check heating/temperature/time control switch E13, renew if necessary → Chapter.
Pre-selection clock with temperature regulator E187 (01.96▸) defective.Check pre-selection clock with temperature regulator E187, renew if necessary.
Short circuitVehicles with camping equipment:
Short circuit in wiring and/or connectors to heater control unit J65S via operating and display unit for camping equipment E153.Check wiring and/or connectors using current flow diagram.
Operating and display unit for camping equipment E153 defective.Check operating and display unit for camping equipment E153, renew if necessary Rep. Gr.76.
Fault code number and meaningPossible cause of faultRectifying fault
064
Flame monitor G64
InterruptionInterruption in wiring and/or connectors to heater control unit J65 via printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and flame monitor G64.Check wiring and/or connectors using current flow diagram.
Flame monitor G64 defectiveCheck flame monitor G64, renew if necessary → Chapter.
065
Flame monitor G64
Short circuitShort circuit in wiring and/or connectors to heater control unit J65 via printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 and flame monitor G64.Check wiring and/or connectors using current flow diagram.
Flame monitor G64 defectiveCheck flame monitor G64, renew if necessary → Chapter.
Printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372 defective.Renew printed circuit board for temperature sensor, blower motor and glow plug duty cycle control unit J372Chapter.
Fault code number and meaningPossible cause of faultRectifying fault
070Note
Temperature sensor G18
InterruptionInterruption in wiring and/or connectors from operating and display unit for camping equipment E153 via temperature sensor G18.Check wiring and/or connectors using current flow diagram.
Temperature sensor G18 defective.Check temperature sensor G18, renew if necessary → Chapter.
090
Heater control unit J65
defectiveWiring and/or connectors to heater control unit J65 defective.Check wiring and/or connectors using current flow diagram.
Heater control unit J65 defective.Renew heater control unit J65Chapter.

Only displayed on operating and display unit for camping equipment E153

.

Fault code number and meaningPossible cause of faultRectifying fault
091
Heater control unit J65
External interference voltageInterference voltage at heater control unit J65 from onboard power supply. Possible causes: Interference caused by car telephone.Short-distance interference suppressor for windscreen wiper motor, coolant fan or rear window wiper motor defective.Localise and rectify fault.After eliminating the interference voltage, interrogate the fault memory again.
092
093
094
Heater control unit J65
defectiveWiring and/or connectors to heater control unit J65 defective.Check wiring and/or connectors using current flow diagram.
Heater control unit J65 defective.Renew heater control unit J65Chapter.

Parts & tools for this job For 1990 Volkswagen Transporter