Start procedure
After each engine start the flame monitor G64 must inform the heater control unit J162 within 130 seconds after the heating has switched on, that the flame is burning normally. If this not the case, then the heater unit will automatically attempt a second start. If after the second start the flame still does not burn normally, the heater will remain switched off until the auxiliary coolant heater is switched on again.
In partial load mode, combustion air blower V6 operates at reduced rpm and metering pump V54 delivers only approx. 50% of the quantity of fuel (reduced pulse frequency).