Test sequence
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heaters -B4W/D4W- › Test sequence
Test sequence
Disconnect the 8-pin connector “T8i” from the heater unit.
Set the measuring range selector switch on the hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect hand multimeter V.A.G 1526B to chamber “T8i/2” and chamber “T8i/6” of the disconnected 8-pin connector using the cables included in auxiliary measuring set V.A.G 1594C.

Switch on the ignition.
Display on the hand multimeter V.A.G 1526B:
- At ambient temperatures below +5°C ≈ 12 V
- At ambient temperatures above +5°C ≈ 0 V
Unclip ambient temperature switch (1) from the tow ring bracket, front right.

Spray the ambient temperature switch with cold spray, if necessary, and observe the display on hand multimeter V.A.G 1526B.
If the values do not change when ambient temperature switch F38 is sprayed, or if the specified rated values are not achieved:
Check the cables and/or connectors to ambient temperature switch F38 according to the circuit diagram.
If the cables and/or connectors to ambient temperature switch F38 are OK according to the circuit diagram:
Renew ambient temperature switch F38.
Note
- Ambient temperature switch F38 only switches the auxiliary coolant heater on automatically if the coolant temperature is below approx. 50°C and the ambient temperature is below approx. +5°C.