Removing
- Make
- Volkswagen
- Model
- Transporter T5
- Year
- 2003–2015
- Section
- Climatronic - air conditioner with automatic regulation › Removing
‹ Prev Removing retaining plate with defroster flap control motor V107, side vent control motor V262 and centre vent control moNext › Installing
Heating, air conditioningRemoving
Removing
With vehicle diagnosis, testing and information system VAS 5051/ Initiating function service position for control motors → Chapter.
When “SF” appears on display of Climatronic operating unit, switch ignition off.
Note Note!
- After removal, the control motors can be reinstalled only when set in the service position “SF”.
- Replacement parts are supplied set in the service position!
Remove dash panel Rep. Gr.70.
Remove lower retaining plate for footwell flap control motor V261 and left temperature flap control motor V158Chapter.
Remove bolts (3).

Note Note!
- To remove the retaining plate, the bolts (1) are not loosened or removed. They are used for guiding the retaining plate.
Separate connectors.
Pull retaining plate with control motors out downwards.
‹ Prev Removing retaining plate with defroster flap control motor V107, side vent control motor V262 and centre vent control moNext › Installing
Parts & tools for this job For 2003 Volkswagen Transporter
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Transporter 2003 cabin filter