Removing
- Make
- Volkswagen
- Model
- Transporter T5
- Year
- 2003–2015
- Section
- Climatronic - air conditioner with automatic regulation › Removing
‹ Prev temperature flap control motor, left V158Next › Removing and installing footwell flap control motor V261
Heating, air conditioningRemoving
Removing
Remove lower retaining plate (2) for footwell flap control motor V261 and left temperature flap control motor V158Chapter.
Remove bolts (4) (Qty. 3) from temperature flap control motor (A).

Remove control motor from retaining plate (2).
‹ Prev temperature flap control motor, left V158Next › Removing and installing footwell flap control motor V261
Parts & tools for this job For 2003 Volkswagen Transporter