Evaporator - remove and install
- Make
- Volkswagen
- Model
- Up! Brazil-market up!
- Year
- 2014–2021
- Section
- Plenum chamber › Evaporator - remove and install
Evaporator - remove and install
Special tools and workshop equipment requiredService station for air conditioning VAS 6007A or newer model.



Note
- The refrigerant must be previously drained with the service station for air conditioning VAS 6007A, for example.
- Currently used service stations for air conditioning can remain under use⇒ V.A.G. Catalogue workshop equipment
- All refrigerant circuit components that are open must be sealed with proper sealing plugs to prevent humidity from entering.
- Contaminating the environment with refrigerant is a punishable offence.
Warning Risk of pressurized effluent refrigerant!
Risk of freezing the skin and other body parts.
Remove the refrigerant via suction and open the refrigerant circuit.If suction was carried out over 10 minutes and the refrigerant circuit is still not opened, repeat the refrigerant suction process. Re-evaporation creates pressure in the refrigerant circuit.
Remove the plenum chamber (air conditioning) → Chapter.
Disassemble the evaporator housing → Chapter.

Remove the evaporator (3) from the lower part of the evaporator housing (7) .

Observe sealing seating (3) :
Sealing installation position
Installation is performed in reverse sequence to the removal.
Parts & tools for this job For 2014 Volkswagen Up!
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Up! 2014 cabin filter