Checking for leaks
- Make
- Volkswagen
- Model
- XL1 plug-in hybrid
- Year
- 2014–2016
- Section
- Vacuum system › Checking for leaks
Checking for leaks
Special tools and workshop equipment requiredVacuum gauge for brake servo VAS 6721
Remove bonnet General body repairs, exteriorRep. gr.55Bonnet; Removing and installing bonnet.
Connect brake servo tester VAS 6721Chapter.
Open shut-off valve (A).

Close shut-off valves (B) and (C).
Switch on ignition.
Normally, the vacuum that is generated should be between 600 and 950 mbar.
Open shut-off valve (C) to evacuate brake servo.

Switch off ignition.
Read and make a note of measured value shown.
A vacuum decrease of 400 mbar in 12 hours is permissible.
If the vacuum decrease is greater, check for leaks in the following areas:
- Brake servo
- Non-return valve, vacuum hoses with plug-in connectors and vacuum pump
If there are large leaks, the vacuum decreases steeply within a few seconds.
After generation of vacuum, close cut-off valve (A) to check brake servo vacuum system.

After generation of vacuum, close shut-off valve (C) to check vacuum system between brake servo tester and vacuum pump.

Note
- If leaks are determined, renew the respective component.
Open cut-off valve (B) to facilitate removal of hose connections and adapter.
Install in reverse order.
Parts & tools for this job For 2014 Volkswagen XL1
- PARTBrake padsSearch: Volkswagen XL1 2014 brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid
As an Amazon Associate we earn from qualifying purchases.