Checking vacuum generation
Special tools and workshop equipment requiredVacuum gauge for brake servo VAS 6721

Remove bonnet General body repairs, exteriorRep. gr.55Bonnet; Removing and installing bonnet.
Connect brake servo tester VAS 6721Chapter.
Open shut-off valve (A).

Close shut-off valves (B) and (C).
Switch on ignition.
Read measured value shown.
Normally, the vacuum that is generated should be between 600 and 950 mbar.
If the measured value is not reached even through the preconditions (see notes) have been met, the vacuum system must first be checked for leaks.
For comparison purposes, generate the vacuum with the manual vacuum pump VAS 6213Chapter.
Open the shut-off valve to facilitate the removal of hose connections and adapters (B).
Install in reverse order.