volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

A/C - Odor From The Ventilation System|Page 10979 > < A/C - Odor From The Ventilation System|Page 10977
Page 14
background image

-

Clamp cables using strip clamps for existing cables

D5

Location of opening in cable sheath

The cable sheath is cut to drain of condensation.

-

The cut conduit section should be placed at the lowest point in the cable routing.

-

Use butyl tape to seal the grommet.

-

Use existing clamps to clamp up the cables to firewall.

D6

Connection of yellow connector

-

Disconnect the yellow connector from the heater and attach the yellow connector from the cable harness.

-

Install the detached connector in the cable harness other yellow connector.

D7

Connection of orange cable

-

Route the orange cable with connector to driver's side of center console.

-

Locate the black 4-pin accessories connector 

The connector can be connected to accessories (A) or unused (B).
-

(A) If accessories are connected. separate connectors and connect them to both connectors on the new cable harness. 

A/C - Odor From The Ventilation System|Page 10979 > < A/C - Odor From The Ventilation System|Page 10977