Attach the cable hamess to the defroster duct above the glove compartment using strip clamp.

Function verification and information

E10

Check airing cycle is working

-

Connect battery lead and start can

-

Turn A/C system on so the compressor starts. 

The A/C system starts if the temperature exceeds approx. 70°C (45° F).
-

Make up a cable approx 2 meters (6.5 ft) in length to connect battery positive terminal to the connector on the control module Connect to green
cable, connector terminal 6, for at least 30 seconds while compressor is working.

-

Turn off engine

Airing cycle should begin after approx 10 seconds and continue for approx. 1 second.
-

Remove cable between connector and battery.

-

Replace all parts removed

-

Enter radio code if anti-theft coded radio installed.

E11

Information to Car Owner

Carry out operations at the end of this service bulletin.