Automatic Transmission Fluid: Service and Repair

CAUTION:  Use correct grade of fluid.

Gearbox With Drain Plug

-

Remove plug and drain off fluid.

Rear Return Oil Cooler Pipe Connection

-

Undo rear (return) oil cooler pipe connection.

-

Connect transparent plastic tube to pipe refit plug in sump.

-

Add approx. 2 liters of fluid.

1. Start engine and allow to idle.
2. Stop engine when air bubbles appear in hose.
3. Add approx. 2 liters of fluid.
4. Repeat steps 1-2. Reconnect pipe to gearbox.

Gearbox without drain plug

Rear Return Oil Cooler Pipe Connection