940 L4-2.3L SOHC VIN 88 B230F (1992)
Hose/Line HVAC: Mechanical Specifications
Hose and Pipe Connections
Hose and Pipe Connections
1. Coupling
40 Nm
Low Pressure Line to Compressor
2. Coupling
25 Nm
High Pressure Line to Compressor
3. Connection Pipe
18 Nm
Pressure Line
4. Condenser Pipe
25 Nm
Condenser
5. Liquid Line
20 Nm
Condenser
6. Air Receiver
45 Nm
Suction Line
7. Pressostat
3.5 Nm
Finger Tight
8. Coupling
45 Nm
Air Receiver
9, 11. Coupling
30 Nm
Evaporator
10, 12. Coupling
12 Nm
Liquid Line
14. Coupling
10 Nm
Condenser Liquid Line
15. Pressostat
3.5 Nm
Condenser
16. Condenser
20 Nm
New Type Seal Connection
17. Compressor
20 Nm
New Type Seal Connection
18. Union
12 Nm
Expansion Tube (Orifice) Location