volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Starter Motor|Flow of Diagnosis|Page 9948 > < Starter Motor|Flow of Diagnosis|Page 9946
Page 3
background image

 Specified Values

The specified current and voltages given in the second image should be obtained when testing a starter motor. If voltage is not the same as test values the
current can be converted. Values which differ from manufacturers specifications may be caused by the differing capacities of the test bench battery and
standard battery.
 
H7 Conversion to another voltage

Bosch 0 001 311 1..

I

= Manufacturer's specification (410-490 A according to test H6 locked starter motor). 

Ix = Measured current consumption in test bench.
U = Manufacturer's specification (6.5 V according to test H6).
Ux = Measured voltage in test bench.

Starter Motor|Flow of Diagnosis|Page 9948 > < Starter Motor|Flow of Diagnosis|Page 9946