background image

Drying evaporator 

-

Set temperature control to max. heat and blower selector to max. speed.

-

Start engine.

-

Allow engine to run for 2 minutes.

-

Switch off the engine.

-

Allow agent to act for 30 minutes.

-

Start engine.

-

Open car windows.

-

Turn on recirculation, blower fan switch on max. speed and temperature selector to max. heat.

-

Allow engine to run for 10 minutes to allow cleaning agent to dry and form a protective film, and to prevent it from being washed off by
condensate.