volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Firewall|Service and Repair|Page 16435 > < Firewall|Service and Repair|Page 16433
Page 3
background image

Cutting point (2) is located 680 mm (M3) from the end of the member.  

If the member is cut at cutting point (2), remove the upper part of the side member extension.  

Remove the outer part of the cross member cowl panel.  

Installing the inner section of the lower side member

Grind clean.

Apply welding primer. 

Seam-weld the join.

Firewall|Service and Repair|Page 16435 > < Firewall|Service and Repair|Page 16433