volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Reading and Clearing Diagnostic Trouble Codes|Page 8415 > < Reading and Clearing Diagnostic Trouble Codes|Page 8413
Page 48
background image

Checking For an Open-Circuit

Checking For An Open-Circuit

Check the cable between VGLA control module #A23 and fuel tank filler cover opening switch terminal 1 and the cable between fuel tank filler cover
opening switch terminal 3 and ground for an open-circuit See: Diagnostic Trouble Code Tests and Associated Procedures/Related Tests and
Information/Checking Wiring and Terminals - Permanent Faults 

 
Were any faults found in the cables?

Yes

-

See: Checking the Fuel Tank Filler Cover Opening Switch/Verification 

No

-

See: Checking the Fuel Tank Filler Cover Opening Switch/Replacing Component

Replacing Component

Replacing Component

Replace the switch.

After performing this procedure See: Checking the Fuel Tank Filler Cover Opening Switch/Verification

Verification

Verification

Hint: After carrying out the repair check that the fault has been remedied as follows:

-

Ignition off.

-

Reconnect connectors, reinstall components.

-

Ignition on.

Activate the fuel tank filler cover opening switch
Read off the switch status.
The value should be LOW when the switch is activated.

Fault Tracing Information

Fault Tracing Information

Condition

-

No diagnostic trouble codes (DTCs) stored.

Reading and Clearing Diagnostic Trouble Codes|Page 8415 > < Reading and Clearing Diagnostic Trouble Codes|Page 8413