S70 L5-2.4L VIN 61 B5244S (2000)
Checking For an Open-Circuit
Checking For An Open-Circuit
Check the cable between VGLA control module #A23 and fuel tank filler cover opening switch terminal 1 and the cable between fuel tank filler cover
opening switch terminal 3 and ground for an open-circuit See: Diagnostic Trouble Code Tests and Associated Procedures/Related Tests and
Information/Checking Wiring and Terminals - Permanent Faults
Were any faults found in the cables?
Yes
-
See: Checking the Fuel Tank Filler Cover Opening Switch/Verification
No
-
See: Checking the Fuel Tank Filler Cover Opening Switch/Replacing Component
Replacing Component
Replacing Component
Replace the switch.
After performing this procedure See: Checking the Fuel Tank Filler Cover Opening Switch/Verification
Verification
Verification
Hint: After carrying out the repair check that the fault has been remedied as follows:
-
Ignition off.
-
Reconnect connectors, reinstall components.
-
Ignition on.
Activate the fuel tank filler cover opening switch
Read off the switch status.
The value should be LOW when the switch is activated.
Fault Tracing Information
Fault Tracing Information
Condition
-
No diagnostic trouble codes (DTCs) stored.