Possible source

-

Open-circuit in signal cable from hood switch.

-

Open-circuit in hood switch ground lead.

-

Faulty hood switch.

Checking The Signal From The Hood Switch

Checking The Signal From The Hood Switch

-

Ignition on.

-

Hood closed.

Read off the hood switch status.
The value should be LOW when the hood is closed.

Is the value LOW?

Yes

-

Test complete

No

-

See: Checking the Hood Switch/Checking the Connectors 

Checking the Connectors

Checking The Connectors

-

Check the VGLA control module connector and the hood switch connector for contact resistance and oxidation, See: Diagnostic Trouble Code
Tests and Associated Procedures/Related Tests and Information/Checking Wiring and Terminals - Permanent Faults 

-

Ignition on.

-

Hood closed.

Read off the hood switch status.
The value should be LOW when the hood is closed.
If the value is OK the cause of the fault was loose connections in the connectors.

Is the value LOW?

Yes

-

Test complete