volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Refrigerant > < A/C - Air Flow Cycles From Floor To Defrost Vents/Noises|Page 18155
Page 1
background image

Receiver Dryer: Description and Operation

Tracing Agent Fluorescent, Production/After Market

Tracing agent fluorescent, production

The tracing agent is impregnated in a free standing "Dry-Water" cylindrical filter in the drying agent in the receiver.
The tracing agent dissolves and mixes with the A/C compressor oil in the climate control system. The tracing agent is light green in color. It is used to
identify any leakage in the climate control system. If an UV lamp is used, it is easier to see where the fluorescent tracing agent is leaking out.
To fill with refrigerant, see: Refrigerant, filling.
To trace leaks, see: Leak detection, tracer agent or: Leak tracing, electronic leak detector.

Tracing agent fluorescent, aftermarket

Facts about the receiver

The receiver is supplied with tracing agent (see above) for aftermarket orders.

Facts about the tracing agent

-

Volvo has introduced a fluorescent tracing agent for aftermarket use

-

The tracing agent is in liquid form. It is mixed with the A/C compressor oil in the climate control system

-

The tracing agent is light green in color. It is used to identify any leakage in the climate control system

-

If an UV lamp is used, it is easier to see where the fluorescent tracing agent is leaking out.

To fill with tracing agent, see: Filling with fluorescent tracing agent with the refrigerant.

Refrigerant > < A/C - Air Flow Cycles From Floor To Defrost Vents/Noises|Page 18155