V70 XC AWD L5-2.4L Turbo VIN 56 B5254T (1998)
Checking Runout
Check axial runout on the flange and locating pin
NOTE: Only needs to be carried out if the flange has been replaced.
NOTE: Ensure that the measuring faces are absolutely clean.
-
Secure plate 999 5971 in the torque tube and magnetic holder with dial gauge on plate.
-
Check locating pin radial runout, maximum value 0.05 mm (0.00197").
-
Check flange axial runout, maximum value 0.05 mm (0.00197").
-
If values are exceeded move the flange a quarter turn at a time.
NOTE: Always use a new nut.
-
Check runout again until the correct values are obtained.
-
Remove measuring equipment and plate 999 5971.