Catalytic Converter Removal
Special Tools
EN-6129 Oxygen Sensor Remover / Installer
For equivalent regional tools refer to
Special Tools .
1. |
Remove the heated oxygen
sensor (1) from the heated oxygen sensor connector bracket.
|
2. |
Remove the heated oxygen
sensor (1) with the EN-6129 remover / installer
from the catalytic converter (2). |
3. |
Remove the exhaust pressure
sensor hose clamp (5). |
4. |
Remove the exhaust pressure
sensor hose (2) from the catalytic converter (4). |
5. |
Loosen the catalytic converter
clamp (3). |
6. |
Remove the 2 catalytic
converter bracket nuts (6). |
7. |
Remove the catalytic converter
(4) from the catalytic converter bracket (7) and the turbocharger
(1). |
8. |
Remove the catalytic converter
clamp (3). |
9. |
Remove the catalytic converter
gasket. |
|