Radiator Cooling Fan Motor: Diagnostic Trouble Code Tests and Associated Procedures
Radiator and Condenser Fans Circuit C

Radiator and Condenser Fans Circuit Troubleshooting C 

1. Disconnect the fan control relay.
2. Disconnect the radiator fan motor 2P connector.

3. Check for continuity between fan control relay 5P connector terminal No. 4 and radiator fan motor 2P connector terminal No. 2.

Is there continuity?

YES-Go to step 4.
NO-Repair an open in the wire between fan control relay 5P connector terminal No. 4 and radiator fan motor 2P connector terminal No. 2.

4. Remove the condenser fan relay from the underhood fuse/relay box.
5. Disconnect the radiator fan switch A 2P connector.

6. Check for continuity between condenser fan relay 4P connector terminal No. 4 and radiator fan switch A 2P connector terminal No. 2.

Is there continuity?

YES-Go to step 7.
NO-Repair an open in the wire between condenser fan relay 4P connector terminal No. 4 and radiator fan switch A 2P connector terminal No.
2.

7. Install the condenser fan relay.

8. Connect a jumper wire between radiator switch A 2P connector terminals No. 1 and No. 2.
9. Turn the ignition switch ON (II).

Does the radiator fan run?

YES-Replace radiator fan switch A and recheck.
NO-Repair an open in the wire between radiator fan switch A 2P connector terminal No 1 and ground G101, G102.