01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2004)22 · Fault diagnosis
22 · Diagnostics

Climate control too cold

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2004
Section
Climate control › Climate control too cold
Fault diagnosisClimate control too cold

CLIMATE CONTROL TOO COLD

The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.

Results of the tests
1AIR TEMPERATURE CHECKAll OKProblems metOperation
Check the temperature of the air at the vents.Continue to Step 8Ambient temperature at the ventsContinue to Step 2
Temperature at the vents higher than desiredContinue to Step 3
2CHECKING SYSTEM PRESSUREAll OKProblems metOperation
Connect the climate control system to the repressurizing equipment and check the system pressure.Continue to Step 8High and low pressure values below correct figures.Repressurize the system Op. 5040A10
High and low pressure values above correct figures.Continue to Step 3
Low pressure value correct, but high pressure value above correct figure (rapid compressor cycle as engine rpm increases)Continue to Step 4
Low pressure value high and high pressure value below correct figureReplace the compressor Op. 5040A20
High and low pressure vaules do not alter when the air conditioning is activated.Replace the compressor Op. 5040A20
3CONDENSER FAN CHECKAll OKProblems metOperation
Check that the fan cools the condenser correctly.Continue to Step 4Electric fan defectiveReplace the fan Op. 5040C30
4CIRCUIT LOADING CHECKAll OKProblems metOperation
Check that the system loading is not excessive.Continue to Step 5System loading excessive.Restore the correct loading Op. 5040A10
5COOLANT CIRCUIT OBSTRUCTION CHECKAll OKProblems metOperation
Check that the pipes and the filter are not obstructed.Continue to Step 6Pipe from compressor to condenser obstructedReplace the pipe Op. 5040A50
Pipe from condenser to filter obstructedReplace the pipe Op. 5040A52
Pipe from filter to expansion valve obstructedReplace the pipe Op. 5040A64
Filter obstructedReplace the pipe Op. 5040A44
6CONDENSER CHECKAll OKProblems metOperation
Check that the condenser is not blocked.Continue to Step 7Condenser blockedReplace the condenser Op. 5040A40
7EXPANSION VALVE CHECKAll OKProblems metOperation
Check the operation of the expansion valve.Continue to Step 8Expansion valve defectiveReplace the expansion valve Op. 5040B30
8CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists

Parts & tools for this job For 2000 Alfa Romeo 147

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.