01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Alfa Romeo GT Factory Service Manual (2003-2010)22 · Fault diagnosis
22 · Diagnostics

Ignition switch not working

Make
Alfa Romeo
Model
GT Factory Service Manual
Year
2003–2010
Section
Starting › Ignition switch not working
Fault diagnosisIgnition switch not working

IGNITION SWITCH NOT WORKING

When the ignition is turned ON nothing happens and the instruments do not light up. The starter motor does not turn in the (AVV) starting position.

Results of the tests
1BATTERY EFFICIENCY CHECKAll OKProblems encounteredOperation
Check the efficiency of the battery using the appropriate diagnostic equipmentMove on to Step 2Battery not working properlyReplace the battery
2FASTENINGS CHECKAll OKProblems encounteredOperation

Check that the petrol vapour recovery system is working properly

Check the following, in order:

  • Correct fastening and earth connection of the negative battery terminal
  • Correct fastening of positive battery pole and all leads connected to it
  • No oxidation of the lead fastenings
  • Correct fastening and connection between positive pole and junction with maxifuse at the battery
Move on to Step 3Lead fastenings at the battery slackTighten leads
Earth lead frayed

Replace the lead

Op. 5530B22 BATTERY EARTH LEAD - R+R

Connections with slack fasteningsRestore fastenings
Maxifuse burnt out

Check the causes of the blown fuse and replace it: wiring diagram

See E1010 SUPPLY

3SUPPLY CHECKAll OKProblems encounteredOperation
Check switch power supplyMove on to Step 4The power supply does not reach the switchCheck the continuity of the wiring between the Maxifuse in the battery junction unit and the switch
7CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentFault persists: control unit defective

Replace the control unit Op.

1056B82

Search for the problem starting from another symptom

4SWITCH CHECKAll OKProblems encounteredOperation
Check the condition of the switch and that it is working properlyMove on to Step 5Switch contacts not working properly

Replace the switch

Op. 5520A12 IGNITION SWITCH ASSEMBLY - R R FOR VERSIONS WITH AIR BAG

5CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentFault persistsSearch for the problem starting from another symptom

Parts & tools for this job For 2003 Alfa Romeo GT

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.