Disconnecting and connecting battery in luggage compartment
- Make
- Audi
- Model
- A3 Mk3
- Year
- 2012–2020
- Section
- Battery › Disconnecting and connecting battery in luggage compartment
Disconnecting and connecting battery in luggage compartment
Warning Risk of accident.
- Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON when working on pyrotechnic components (e.g. airbags, belt tensioners).

Switch off ignition.
Versions equipped with mechanical ignition lock: Remove ignition key.
Versions equipped with electronic ignition lock: Deposit ignition key outside of vehicle.
Raise luggage compartment floor.
Open cover (3) over negative battery terminal.
Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from battery terminal.

Unplug electrical connector (2) at battery monitor control unit J367(item 3).
When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery in luggage compartment”
Parts & tools for this job For 2012 Audi A3
- TOOLBattery testerSearch: car battery tester