Removing and installing battery in engine compartment
- Make
- Audi
- Model
- A3 Mk3
- Year
- 2012–2020
- Section
- Battery › Removing and installing battery in engine compartment
Removing and installing battery in engine compartment
Note
- If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.

Switch off ignition.
Versions equipped with mechanical ignition lock: Remove ignition key.
Versions equipped with electronic ignition lock: Deposit ignition key outside of vehicle.
Open cover in heat insulation sleeve.
Open cover (4) over negative battery terminal.
Slacken off nut (6) several turns and disconnect battery clamp (5) of earth cable from negative battery terminal.
Open cover (3) over positive battery terminal.
Slacken off nut (2) several turns and disconnect battery clamp (1) of positive cable from positive battery terminal.
Pull heat insulation sleeve (4) upwards slightly.

Remove bolt (2) on battery retainer plate (1).
Pull battery (3) out of battery tray and lift out of engine compartment.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Installation is carried out in the reverse order; note the following:
Note
- Only install maintenance-free batteries with the specifications “TL82506” (from December 1997 onwards) and “VW75073” (from August 2001 onwards).
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery in battery tray (1) so that battery base strip makes contact at bottom and side of stop (arrows).

Fit battery retainer plate (2).

Tighten bolt (1) for battery retainer plate.
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (3) of positive cable by hand to positive battery terminal “+” and tighten nut (4).
Country-specific version: Unplug electrical connector (2) at battery monitor control unit J367(item 3).

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
Check that battery is firmly secured after installing.
If the battery is renewed, the new battery must be adapted.
Connect Vehicle diagnostic tester.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 19 - Data bus diagnostic interface - J533
- 19 - Data bus diagnostic interface, functions
- 19 - Adaption
- 19 - Adapt battery
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery in engine compartment”
Parts & tools for this job For 2012 Audi A3
- PARTEngine gasket setSearch: Audi A3 2012 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.