Removing and installing battery in luggage compartment
- Make
- Audi
- Model
- A3 Mk3
- Year
- 2012–2020
- Section
- Battery › Removing and installing battery in luggage compartment
Removing and installing battery in luggage compartment
Note
- If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.
Switch off ignition.
Versions equipped with mechanical ignition lock: Remove ignition key.
Versions equipped with electronic ignition lock: Deposit ignition key outside of vehicle.
Raise luggage compartment floor.
Open cover (3) over negative battery terminal.

Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from battery terminal.
Open cover (1) over positive battery terminal.

Slacken off nut (3) several turns and disconnect battery clamp (2) of positive cable from positive battery terminal.
Unscrew nuts (2, 5) and detach retainer (4).

Remove battery cover (6).
Remove nut (1).
Lift off battery retainer plate (3).
Pull off hose (7) for central gas venting system.
Lift battery out of luggage compartment.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Note
- Only install maintenance-free batteries with the specifications “TL82506” (from December 1997 onwards) and “VW75073” (from August 2001 onwards).
- If a leakproof, deep-cycle VRLA or AGM battery was fitted as original equipment, this type of battery must also be installed as a replacement.
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery and slide into retaining brackets (1, 2, 3) as far as stop (arrows).

Fit hose for central gas venting system.
Further installation is carried out in the reverse order; note the following:
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (2) of positive cable by hand to positive battery terminal “+” and tighten nut (3).

Close cover (1) over positive battery terminal.
Unplug electrical connector (2) at battery monitor control unit J367(item 3).

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
Check that battery is firmly secured after installing.
If the battery is renewed, the new battery must be adapted.
Connect Vehicle diagnostic tester.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 19 - Data bus diagnostic interface - J533
- 19 - Data bus diagnostic interface, functions
- 19 - Adaption
- 19 - Adapt battery
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery in luggage compartment”
Parts & tools for this job For 2012 Audi A3
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.