Removing and installing desiccant cartridge - Denso condenser
- Make
- Audi
- Model
- Q3 8U
- Year
- 2011–2018
- Section
- Refrigerant circuit › Removing and installing desiccant cartridge - Denso condenser
Removing and installing desiccant cartridge - Denso condenser
Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.

Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Remove lock carrier cover General body repairs, exteriorRep. gr.63Bumper (front); Removing and installing attachments.
Check pressure in refrigerant circuit via pressure gauge of air conditioner service station Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
- Only remove the plug when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Unscrew plug (A).
Lift dryer mount (C) with desiccant cartridge (D) out of condenser.
Using e.g. a commercially available gripper tool, pull filter element (E) upwards out of condenser.
Seal open receiver with plug (1) to prevent ingress of dirt and moisture.
Install in reverse order of removal; note the following:
Note
- The plug, O-ring and desiccant cartridge must always be renewed after the receiver has been opened Electronic parts catalogue.
Check threads and sealing surfaces of receiver at condenser for dirt or damage via opening.
Note
- Keep bag with air-tight seal containing desiccant cartridge closed as long as possible. Only open bag immediately before inserting desiccant cartridge in condenser. After opening bag, desiccant cartridge soon becomes saturated with moisture from ambient air and becomes unusable.
- Lubricate O-ring of plug slightly with refrigerant oil before fitting → Chapter.
Insert filter element (E) in correct position in receiver of condenser.

Take desiccant cartridge out of its bag and insert it in dryer mount.
Insert dryer mount together with desiccant cartridge (D) in receiver of condenser.
Fit and screw in plug (A).
Install lock carrier cover General body repairs, exteriorRep. gr.63Bumper (front); Removing and installing attachments.
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Start up air conditioner after charging refrigerant circuit → Chapter.
As a final step, interrogate event memory and erase any entries displayed Vehicle diagnostic tester (“Guided Fault Finding”).
- Chapter“Exploded view - condenser, desiccant cartridge”
Parts & tools for this job For 2011 Audi Q3
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi Q3 2011 cabin filter