01 4-cylinder direct injection engine (1.8 ltr., 2.0 ltr. 4V TFSI, generation II)02 Fuel supply system, petrol engines03 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI EA 211)04 4-cylinder direct injection engine (1.8 ltr., 2.0 ltr. 4V TFSI, generation III)05 4-cylinder TDI engine (2.0 ltr. 4-valve common rail EA 189 - generation II)06 Fuel supply system, diesel engines07 5-cylinder direct injection engine (2.5 ltr. 4-valve TFSI)08 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)09 Technical data for engines10 Rear final drive 0AY, 0BR, 0BS, 0CR11 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB12 7-speed dual clutch gearbox 0BH (S tronic)13 6-speed manual gearbox 02Q, 0BB14 6-speed manual gearbox 0A615 6-speed dual clutch gearbox 02E16 Running gear: Specifications for testing the braking force (according to German legislation)17 Running gear: Trailer Operation Guide18 Running gear, axles, steering19 Brake system20 Running gear: Wheel/Tyre Guide21 Heating, air conditioning22 Electrical system23 Electrical: Communication24 General body repairs, exterior25 General body repairs, interior
Audi Q3 8U (2011-2018)21 · Heating, air conditioning
21 · Heating & A/C

Removing and installing desiccant cartridge - Denso condenser

Make
Audi
Model
Q3 8U
Year
2011–2018
Section
Refrigerant circuit › Removing and installing desiccant cartridge - Denso condenser
Heating, air conditioningRemoving and installing desiccant cartridge - Denso condenser

Removing and installing desiccant cartridge - Denso condenser

Air conditioner with refrigerant R134a

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.

Special tools and workshop equipment requiredCommercially available gripper tool

Removing

A87-10639

Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).

Remove lock carrier cover General body repairs, exteriorRep. gr.63Bumper (front); Removing and installing attachments.

Check pressure in refrigerant circuit via pressure gauge of air conditioner service station Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.

  • Only remove the plug when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.

Unscrew plug (A).

Lift dryer mount (C) with desiccant cartridge (D) out of condenser.

Using e.g. a commercially available gripper tool, pull filter element (E) upwards out of condenser.

Seal open receiver with plug (1) to prevent ingress of dirt and moisture.

Installing

Install in reverse order of removal; note the following:

Note

  • The plug, O-ring and desiccant cartridge must always be renewed after the receiver has been opened Electronic parts catalogue.

Check threads and sealing surfaces of receiver at condenser for dirt or damage via opening.

Note

  • Keep bag with air-tight seal containing desiccant cartridge closed as long as possible. Only open bag immediately before inserting desiccant cartridge in condenser. After opening bag, desiccant cartridge soon becomes saturated with moisture from ambient air and becomes unusable.
  • Lubricate O-ring of plug slightly with refrigerant oil before fitting → Chapter.

Insert filter element (E) in correct position in receiver of condenser.

A87-10639

Take desiccant cartridge out of its bag and insert it in dryer mount.

Insert dryer mount together with desiccant cartridge (D) in receiver of condenser.

Fit and screw in plug (A).

Install lock carrier cover General body repairs, exteriorRep. gr.63Bumper (front); Removing and installing attachments.

Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).

Start up air conditioner after charging refrigerant circuit → Chapter.

As a final step, interrogate event memory and erase any entries displayed Vehicle diagnostic tester (“Guided Fault Finding”).