Removing and installing desiccant cartridge - Modine condenser
- Make
- Audi
- Model
- Q3 8U
- Year
- 2011–2018
- Section
- Refrigerant circuit › Removing and installing desiccant cartridge - Modine condenser
Removing and installing desiccant cartridge - Modine condenser
Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.

Remove lock carrier cover General body repairs, exteriorRep. gr.63Bumper (front); Removing and installing attachments.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Remove protective cap (1).
Check pressure in refrigerant circuit via pressure gauge of air conditioner service station Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
- Only remove the circlip when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Press cap (1) in slightly.
Detach circlip (arrow) and pull cap out of condenser (2) using an M12 bolt.
Prepare a length of welding wire (∅ 2 mm) with the following dimensions:

To prevent damaging the condenser, it is important to hook the welding wire into the strainer as shown in the illustration.

Using welding wire (1), carefully pull filter element (strainer) (2) out of receiver.
Seal open receiver with cap (1) to prevent ingress of dirt and moisture.


Remove protective cap (1) using socket T70 T10128.
Check pressure in refrigerant circuit via pressure gauge of air conditioner service station Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
- Only remove the circlip when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Press cap (1) in slightly.
Detach circlip (arrow) and pull cap out of condenser (2) using an M12 bolt.
Using long-nose pliers, pull dryer unit (1) out of condenser (2).

Seal open receiver with cap to prevent ingress of dirt and moisture.
Install in reverse order of removal; note the following:
Note
- The cap, O-rings, desiccant cartridge and filter element (strainer) must always be renewed after the receiver has been opened Electronic parts catalogue.
Check sealing surfaces of receiver at condenser for dirt or damage via opening.

Insert filter element (with strainer) (2) in correct position in receiver of condenser.
Make sure filter element is pressed in as far as possible.Note
- Keep bag with air-tight seal containing desiccant cartridge closed as long as possible. Only open bag immediately before inserting desiccant cartridge in condenser. After opening bag, desiccant cartridge soon becomes saturated with moisture from ambient air and becomes unusable.
Take desiccant cartridge out of its bag and insert it in receiver of condenser.

Take dryer unit (1) out of its bag and insert it in condenser (2).

Insert cap (1) and press it downwards until circlip (arrow) can engage in the groove.
Note
- Coat O-rings of cap lightly with refrigerant oil before fitting → Chapter.
Version 1: Press on protective cap.

Version 2: Screw in protective cap using socket T70 T10128.
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Start up air conditioner after charging refrigerant circuit → Chapter.
As a final step, interrogate event memory and erase any entries displayed Vehicle diagnostic tester (“Guided Fault Finding”).