Heating, air conditioningSystem overview - refrigerant circuit
System overview - refrigerant circuit

- Air conditioner compressor regulating valve N280
Checking Vehicle diagnostic tester (“Guided Fault Finding”), Chapter“Checking cut-in signal for air conditioner compressor regulating valve N280” and Current flow diagrams, Electrical fault finding and Fitting locationsNoteCertain malfunctions of N280 (e.g. sticking valve or open circuit in coil) can lead to problems with the air conditioner compressor (no cooling output from air conditioner, evaporator icing up etc.). If N280 (and not the air conditioner compressor itself) is the cause of the problem, the air conditioner compressor can be serviced by renewing N280Air conditioner with refrigerant R134aRep. gr.87Renewing components of refrigerant circuit. N280 is not available as replacement part for all air conditioner compressors. If N280 cannot be obtained separately for a particular air conditioner compressor (different versions available), the entire air conditioner compressor must be renewed if problems occur Electronic parts catalogue. - Air conditioner compressor
Exploded view → Chapter - High-pressure safety valveCautionDanger from escaping pressurised refrigerant if valve is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve.
- Oil drain plug
- Cap
With seal
Always screw on - Service connection on low-pressure side
For measuring and dischargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. - Evaporator
- Expansion valve
Exploded view → Chapter - High-pressure sender G65
Checking Vehicle diagnostic tester (“Guided Fault Finding”), Chapter“Checking pressure signal from high-pressure sender G65” and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Connection with valve
- Condenser
Exploded view → Chapter - Receiver
Receiver is integrated in condenser - Service connection on high-pressure side
For measuring, discharging and chargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. - Cap
With seal
Always screw on - Pulley
Renewing → Chapter
Currently the pulley cannot be renewed separately on air conditioner compressors manufactured by “Delphi”NoteVehicles with a 5-cylinder engine (Audi RS Q3) have 2 poly V-belts on the air conditioner compressor. The air conditioner compressor is therefore provided with a double-belt pulley.