Removing and installing expansion valve
- Make
- Audi
- Model
- R8 Mk2
- Year
- 2015–2023
- Section
- Refrigerant circuit › Removing and installing expansion valve
Removing and installing expansion valve
Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.
Note
- Specific tools are required for discharging the refrigerant circuit; such work may only be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with air conditioner service station).
Switch off ignition.
Remove luggage compartment liner (with cowl panel trim) General body repairs, interiorRep. gr.70Luggage compartment trim panels; Overview of fitting locations - luggage compartment trim panels.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Remove bolts (1).

Detach refrigerant lines (2) with internal heat exchanger from expansion valve (3).
Remove bolts (1).

Remove expansion valve (2).
Seal off open lines and connections (7, 8) with clean plugs from engine bung set VAS 6122.
Installation is carried out in the reverse order; note the following:
Check grommet (6) for correct seating and damage
Check refrigerant pipes to evaporator (7, 8) and the connections at expansion valve (2) for dirt and damage
Note
- Even minor damage to the connections (e.g. a small scratch) could cause leakage.
- Ensure absolute cleanliness when working (even the slightest contamination, e.g. a single hair at the connections, could cause leakage).
Fit retainer (5) on the refrigerant pipes to evaporator (7, 8).
Insert O-rings (3, 4) at connecting pipes to evaporator (7, 8).
Note
- Renew O-rings (3, 4); for correct version, refer to Electronic parts catalogue.
- Lubricate O-ring with refrigerant oil before installing → Chapter.
- Pay attention to correct positioning of the O-rings (3, 4) on the refrigerant pipes of evaporator (7, 8).
- Observe the different tightening torques of the bolts.
- There are different versions of the expansion valve (2) (identical housing, but different characteristic curve). For correct version refer to Electronic parts catalogue.
Install expansion valve (2).
Fit bolts (1) (tightening torque: 9 Nm).
Check connections at refrigerant lines (2) with internal heat exchanger and connections at expansion valve (3) for dirt and damage

Note
- Even minor damage to the connections (e.g. a small scratch) could cause leakage.
- Ensure absolute cleanliness when working (even the slightest contamination, e.g. a single hair at the connections, could cause leakage).
Check grommet (7) for correct seating and damage.
Insert O-rings (4, 5) in groove of respective connection.
If fitted, check that dowel pin (6) is not damaged and is seated correctly.
Note
- Renew O-rings (4, 5); for correct version, refer to Electronic parts catalogue.
- Lubricate O-ring with refrigerant oil before installing → Chapter.
- Pay attention to correct positioning of the O-rings (4, 5) on the connections of refrigerant lines (2).
- Depending on the version, the dowel pin (6) can be fitted at the connections of refrigerant line (2) or at expansion valve (3). The dowel pin (6) might not be fitted on certain versions.
Insert refrigerant lines (2) with internal heat exchanger at expansion valve.
Fit bolts (1) (tightening torque: 9 Nm).
Check refrigerant lines (2) with internal heat exchanger for correct routing and fastening in the corresponding retainers.
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Re-install removed components in reverse order.
Start up air conditioner after charging refrigerant circuit → Chapter.
Interrogate the event memory of E87 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.
As a final step, check operation of heater and air conditioner.
Parts & tools for this job For 2015 Audi R8
- PARTEngine gasket setSearch: Audi R8 2015 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set