Workshop Manuals Factory service & repair Audi
01 Technical data for engines02 10-cylinder direct petrol injection engine (5.2 ltr. 4-valve)03 Fuel supply system, petrol engines04 Front final drive 0D405 7-speed dual clutch gearbox 0BZ06 Brake system07 Running gear, axles, steering08 Heating, air conditioning09 Electrical system10 Electrical: Communication11 General body repairs, interior12 General body repairs, exterior
Audi R8 Mk2 (2015-2023)08 · Heating, air conditioning
08 · Heating & A/C

System overview - refrigerant circuit

Make
Audi
Model
R8 Mk2
Year
2015–2023
Section
Refrigerant circuit › System overview - refrigerant circuit
Heating, air conditioningSystem overview - refrigerant circuit

System overview - refrigerant circuit

Air conditioner with refrigerant R134a

HD = High-pressure side

ND = Low-pressure side

Note

  • The arrows indicate the direction of refrigerant flow.

A87-12073
  • Air conditioner compressor regulating valve N280
    Checking Vehicle diagnostic tester in “Guided Fault Finding” mode and Current flow diagrams, Electrical fault finding and Fitting locationsNoteCertain malfunctions of N280 (e.g. sticking valve or open circuit in coil) can lead to problems with the air conditioner compressor (no cooling output from air conditioner, evaporator icing up etc.). If N280 (and not the air conditioner compressor itself) is the cause of the problem, the air conditioner compressor can be serviced by renewing N280Air conditioner with refrigerant R134aRep. gr.87Renewing components of refrigerant circuit. N280 is not available as a replacement part for all air conditioner compressors. If N280 cannot be obtained separately for a particular air conditioner compressor (different versions available), the entire air conditioner compressor must be renewed if problems occur Electronic parts catalogue.
  • Air conditioner compressor
    Exploded view → Chapter and ChapterNoteMake sure that the refrigerant lines are not in contact with other components and cannot come into contact during operation (noise) Electronic parts catalogue.
  • Connection in refrigerant line - low-pressure side
    To air conditioner compressor
    Exploded view → Chapter
  • Cap
    With seal
    Always screw on
  • Service connection on low-pressure side
    For measuring and dischargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
  • Refrigerant line with internal heat exchanger
    In the internal heat exchanger, the hot liquid refrigerant flowing through the high-pressure side gives off energy to the cold refrigerant vapour flowing through the low-pressure side, thus enhancing the efficiency of the air conditioner.
    Removing and installing → Chapter
  • Expansion valve
    Exploded view → Chapter
    Removing and installing → Chapter
  • Evaporator
    Installed in heater and air conditioner
    Exploded view → Chapter
  • Cap
    With seal
    Always screw on
  • Service connection on high-pressure side
    For measuring, discharging and chargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
  • Receiver with dryer
    Exploded view → Chapter
  • Right condenser
    Exploded view → Chapter
  • Left condenser
    Exploded view → Chapter
  • Connection with valve
    On refrigerant line to left condenser → Chapter
  • High-pressure sender G65
    Checking Vehicle diagnostic tester in “Guided Fault Finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
    Removing and installing → Chapter
  • Connection in refrigerant line - high-pressure side
    From condenser
    Exploded view → Chapter
  • Oil drain plugCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
    Different versions Electronic parts catalogue
    Tightening torque:Denso air conditioner compressor: 30 NmSanden air conditioner compressor: 10 Nm
  • High-pressure safety valveCautionDanger from escaping pressurised refrigerant if valve is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve.
  • Air conditioner compressor drive unit
    Exploded view → Chapter and → Chapter
    Replacing air conditioner compressor drive unit Chapter“Detaching and attaching air conditioner compressor drive unit”

Parts & tools for this job For 2015 Audi R8