System overview - refrigerant circuit
- Make
- Audi
- Model
- R8 Mk2
- Year
- 2015–2023
- Section
- Refrigerant circuit › System overview - refrigerant circuit
Heating, air conditioningSystem overview - refrigerant circuit
System overview - refrigerant circuit
Note
- The arrows indicate the direction of refrigerant flow.

- Air conditioner compressor regulating valve N280
Checking Vehicle diagnostic tester in “Guided Fault Finding” mode and Current flow diagrams, Electrical fault finding and Fitting locationsNoteCertain malfunctions of N280 (e.g. sticking valve or open circuit in coil) can lead to problems with the air conditioner compressor (no cooling output from air conditioner, evaporator icing up etc.). If N280 (and not the air conditioner compressor itself) is the cause of the problem, the air conditioner compressor can be serviced by renewing N280Air conditioner with refrigerant R134aRep. gr.87Renewing components of refrigerant circuit. N280 is not available as a replacement part for all air conditioner compressors. If N280 cannot be obtained separately for a particular air conditioner compressor (different versions available), the entire air conditioner compressor must be renewed if problems occur Electronic parts catalogue. - Air conditioner compressor
Exploded view → Chapter and ChapterNoteMake sure that the refrigerant lines are not in contact with other components and cannot come into contact during operation (noise) Electronic parts catalogue. - Connection in refrigerant line - low-pressure side
To air conditioner compressor
Exploded view → Chapter - Cap
With seal
Always screw on - Service connection on low-pressure side
For measuring and dischargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. - Refrigerant line with internal heat exchanger
In the internal heat exchanger, the hot liquid refrigerant flowing through the high-pressure side gives off energy to the cold refrigerant vapour flowing through the low-pressure side, thus enhancing the efficiency of the air conditioner.
Removing and installing → Chapter - Expansion valve
Exploded view → Chapter
Removing and installing → Chapter - Evaporator
Installed in heater and air conditioner
Exploded view → Chapter - Cap
With seal
Always screw on - Service connection on high-pressure side
For measuring, discharging and chargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. - Receiver with dryer
Exploded view → Chapter - Right condenser
Exploded view → Chapter - Left condenser
Exploded view → Chapter - Connection with valve
On refrigerant line to left condenser → Chapter - High-pressure sender G65
Checking Vehicle diagnostic tester in “Guided Fault Finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Connection in refrigerant line - high-pressure side
From condenser
Exploded view → Chapter - Oil drain plugCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
Different versions Electronic parts catalogue
Tightening torque:Denso air conditioner compressor: 30 NmSanden air conditioner compressor: 10 Nm - High-pressure safety valveCautionDanger from escaping pressurised refrigerant if valve is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve.
- Air conditioner compressor drive unit
Exploded view → Chapter and → Chapter
Replacing air conditioner compressor drive unit Chapter“Detaching and attaching air conditioner compressor drive unit”
Parts & tools for this job For 2015 Audi R8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi R8 2015 cabin filter
As an Amazon Associate we earn from qualifying purchases.