SRX AWD V6-3.6L (2008)
6. Install the condenser tube bolt.
Tighten the bolt to 9 N.m (80 lb in).
7. Install a new O-ring to the discharge line. Refer to O-Ring Replacement (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair) .
8. Connect the discharge line to the condenser.
9. Install the discharge line bolt.
Tighten the bolt to 9 N.m (80 lb in).