01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën C5 (X7) Factory Workshop Manual (2008-2017)01 · Engine
01 · Engine

Removing - Refitting: Air inlet manifold

Make
Citroën
Model
C5 (X7) Factory Workshop Manual
Year
2008–2017
Section
Cylinder head › Removing - Refitting: Air inlet manifold
EngineRemoving - Refitting: Air inlet manifold

Removing - Refitting: Air inlet manifold

Citroën C5 (X7) · Removal-fitting · Ref. B1HG01J5P0

Applies to: 2.0 HDi 163 PEF

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Removing

Remove the engine style cover.

Disconnect the ancillaries battery.

For: 2.0 HDi 163 PEF

Remove:

Remove:

Figure b1hg0f1d

Unfasten and move aside:

  • The electrical harness   (at "a")
  • The main engine harness (1)

Remove:

Figure b1hg0f3d

Remove the bolts (4).

Figure b1hg30jd

Unclip:

  • The diesel fuel manual priming pump (5)
  • The bracket (9) for the diesel fuel manual priming pump (5); By means of a screwdriver   (at "b")

Release and move aside the electrical harness (8).

Remove:

  • The bolts (7)
  • The top timing cover (6)
Figure b1hg0f7d

Remove the bolts (10).

Tilt the electrovalve heat shield slightly rearwards.

CAUTION: The operation on the electrovalves is done with the help of a mirror.

Unplug: The "ON/OFF" electrovalve   (at "c").

Uncouple:

  • The vacuum pipe   (at "d")
  • The vacuum pipe   (at "e")
  • The vacuum pipe   (at "f")
Figure b1hg40sd

Remove the screws (11b), (11c) and (11a).

boltslength
(11a)42 mm
(11b)70 mm
(11c)55 mm
Figure b1hg0fid

Remove the air inlet manifold (12).

Disconnect the electrovalves   (at "g").

CAUTION: Cover the openings of the air inlet circuit.

Remove the air inlet manifold (12).

2. Preparation

CAUTION: Clean the sealing face on the valve cover; Using a special degreaser (Refer to the products catalogue).

Figure b1hg0fjd

CAUTION: Replace the seals (16), (17) with new seals.

In the case of a replacement, save and refit on the new component:

  • The vacuum pipes (13)
  • The electrovalve breather (14)
  • The exhaust gas recycling duct (18); With new seals

In the case of a replacement, save and refit on the new component: The control electrovalves (15).

Oil the O-rings (17) before refitting; With engine oil.

3. Refitting

CAUTION: Adhere to the tightening torques.

Offer up the air inlet manifold (12) facing the cylinder head.

Connect the electrovalves () (as "g").

Refit the air inlet manifold (12).

Figure b1hg0nbd

CAUTION: Respect the tightening sequence indicated.

Refit the bolts (11a), (11b) and (11c):

  • Do up the bolts
  • Slacken the bolts
  • Retighten the bolts to the correct torque

Couple up:

  • The vacuum pipe (as "f")
  • The vacuum pipe (as "e")
  • The vacuum pipe (as "d")

Connect   The "ON/OFF" electrovalve   (at "c").

Refit:

  • The bolts (10)
  • The top timing cover (6)
  • The bolts (7)

Clip the electrical harness (8).

For: 2.0 HDi 163 PEF

Refit:

Refit:

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.

Refit the engine style cover.