Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën C5 (X7) Factory Workshop Manual (2008-2017)01 · Engine
01 · Engine

Removing - Refitting: Inlet air metering unit

Make
Citroën
Model
C5 (X7) Factory Workshop Manual
Year
2008–2017
Section
Cylinder head › Removing - Refitting: Inlet air metering unit
EngineRemoving - Refitting: Inlet air metering unit

Removing - Refitting: Inlet air metering unit

Citroën C5 (X7) · Removal-fitting · Ref. B1HG01HVP0

Applies to: 2.0 HDi 163 PEF

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Removing

Remove the engine style cover.

Figure b1bg0hsd

Remove the mountings (1).

Figure b1hg0n6d

CAUTION: With care, lift the bumper top baffle to gain access to the fastening (2).

Remove:

  • The clip (2)
  • The air inlet duct (3)
Figure b1hg0n7d

CAUTION: Protect the engine cooling radiator to prevent damage to the fins.

Unplug; Using a thin screwdriver:

  • The inlet air mixer sensors (as "a")
  • The inlet air pressure/temperature sensor (as "b")

Release and move aside the electrical harness (4).

Uncouple: The air inlet unions (5).

Figure b1hg0n8d

Uncouple: The vacuum pipes (as "c").

Unfasten and move aside: The vacuum pipes (6).

Figure b1hg16fd

Slacken the mountings (7) sufficiently to allow lateral movement of the support (8).

Figure b1hg16gd

Remove:

  • The bolts (9)
  • The bolts (10)
  • The inlet air metering unit (11)

2. Refitting

CAUTION: Adhere to the tightening torques.

Figure b1hg16hd

CAUTION: Check the condition of the seal (12); Exchange it if necessary.

Position:

  • The seal (12) on the mixer unit (11)
  • The inlet air metering unit (12)

Tightening procedure: Inlet air metering unit assembly + support:

  • Tighten the mountings (7) by hand; The support (8) must be properly seated, allowing lateral movement
  • Tighten the bolts (10) to the specified torque
  • Tighten the bolts (9) to the specified torque
  • Tighten the mountings (7) to the specified torque

Couple up:

  • The vacuum pipes (as "c")
  • The air inlet unions (5)

Clip in place:

  • The vacuum pipes (6)
  • The electrical harness (4)

Connect:

  • The inlet air mixer sensors (as "a")
  • The inlet air pressure/temperature sensor (as "b")

CAUTION: Remove the protection on the cooling radiator.

Refit:

  • The air inlet duct (3)
  • The clip (2)
  • The mountings (1)

Refit the engine style cover.

Parts & tools for this job For 2008 Citroën C5

As an Amazon Associate we earn from qualifying purchases.