Bleeding: Additional heater unit power supply
- Make
- Citroën
- Model
- C6 Factory Workshop Manual
- Year
- 2005–2012
- Section
- Cooling system › Bleeding: Additional heater unit power supply
Bleeding: Additional heater unit power supply
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
[1] Pliers for removing CLIC clips 4145-T.
[2] plugs kit (-).0194/2-E.
2. Preliminary operation
Remove the front left side mud guard.
3. Bleeding
N.B.: Perform bleeding operations, when carrying out repairs either on the additional heating unit or on its fuel supply circuit.
Uncouple and blank the fuel supply pipe (1); Using tools [1] and [2].
Position a receptacle underneath the fuel supply pipe (1).
Start the engine.
Allow the fuel to flow out for approx. 15 seconds.
Pinch the fuel supply pipe (1) 30 mm from the end; Using pliers.
CAUTION: Do not damage the fuel supply pipe.
Couple the fuel supply pipe (1) on the heating unit (2).
Stop the engine.
4. Additional operation
Refit the front left hand splash-shield.
Parts & tools for this job For 2005 Citroën C6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Citroën C6 2005 cabin filter
As an Amazon Associate we earn from qualifying purchases.