ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Removing
ESSENTIAL: Respect the safety and cleanliness recommendations that are specific to high pressure diesel injection (HDi) engines.
Remove the engine style cover.
Drain the cooling system.
Place a tray underneath the vehicle to permit clean draining of the system.
Remove:
- The (1) bolt: Exhaust gas recirculation tube (2) (front)
- The bolt: Exhaust gas recirculation tube (rear)
- The 2 bolts (3)
Disconnect the connectors (at "a").
Unclip: Fuel hoses (6) (at "b", "c").
Remove:
- The bolt (4)
- The bracket (5)
Pull the fuel piping away (6).
Release the clips (8), (10) and (11).
Remove:
- The exhaust gas recycling pipe (2) (front)
- The clip (12)
- The sleeve (13)
- The (7) bolt
- The air mixer unit (9) (push forwards)
Disconnect the connector (at "d").
Detach and move aside:
- The pipe (15) (at "e", "f")
- The pipe (14)
Remove bolts (18).
Move the mounting (17) aside.
Uncouple the pipe (16) (at "g").
Disconnect the connector (at "j").
Remove:
- The oil pressure sensor (19)
- The clip (20)
Uncouple the pipe (16) (at "h").
Remove:
- The screws (22) of the coolant outlet housing (21)
- The thermostat (21)
2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: At refitting, all the removed seals must be replaced with new seals.
Refit:
- The coolant outlet (21) complete with new seals
- The screws (22) of the coolant outlet housing (21)
- The clip (20) on the hose (16)
Connect the hose (14) (at "h").
Refit the oil pressure sensor (19).
Connect the connector (at "j").
Connect the hose (16) (at "g").
Refit:
- The bracket (17)
- The (18) bolt
Couple up:
- The pipe (14)
- The pipe (15) (at "e", "f")
Connect the connector (at "d").
Refit:
- The air mixer unit (9)
- The (7) bolt
- The sleeve (13)
- The clip (12)
- The exhaust gas recycling pipe (2) (front)
Clip: The collars (8), (10) and (11).
Refit:
- The bracket (5)
- The bolt (4)
Clip: Fuel hoses (6) (at "b", "c").
Connect the connectors (at "a").
Refit:
- The 2 bolts (3)
- The bolt: Exhaust gas recirculation tube (rear)
- The (1) bolt: Exhaust gas recirculation tube (2) (front)
Fill and bleed the cooling system.
Refit the engine style cover.
Parts & tools for this job For 2005 Citroën C6