Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën DS5 Factory Workshop Manual (2011-2015)01 · Engine
01 · Engine

Check: Air supply circuit

Make
Citroën
Model
DS5 Factory Workshop Manual
Year
2011–2015
Section
Air and fuel supply › Check: Air supply circuit
EngineCheck: Air supply circuit

Check: Air supply circuit

Citroën DS5 · Checks · Ref. B1HD014KP0

Applies to: Hybrid traction chain and 2.0 HDi 163 PEF or Without hybrid traction chain and 2.0 HDi 163 PEF

ESSENTIAL: Observe the safety and cleanliness recommendations.

Equipment.

Diagnostic station.

1. Tooling

ToolsReferencesDesignation
Figure e5ab0jwt
[DA16]Manual pressure-vacuum pump with adaptors
Figure e5ag03lt
[1617-J]Sealing plugs

2. Flow chart: Vacuum circuit

2.1. Components

Figure b1hdz6np

(1) vacuum pump.

(2) Air inlet manifold with integral vacuum reserve.

(3) Remote breather.

(4) Inlet air mixer control electrovalve   (according to equipment).

(5) Control capsule for the inlet air mixer   (according to equipment).

(6) Inlet air cooling solenoid valve.

(7) Control capsule for the inlet air cooler by-pass mixer.

(8) Turbocharger pressure regulation solenoid valve.

(9) Variable geometry control capsule (turbocharger).

(10) Electrovalve controlling the EGR exchanger by-pass.

(11) Control capsule for the exhaust gas cooler by-pass flap.

2.2. Link: tyre

Figure b1hdz6qp

"a" Vacuum generation circuit with take-off for the exhaust gas recovery control circuit.

Circuit upstream of the electrovalves:

  • "B" Vacuum coupling circuit on the proportional control electrovalves (4) and (6)
  • "C" Vacuum coupling circuit on the proportional control electrovalves (8) and "ON/OFF" (10)

Circuit downstream of the electrovalves:

  • "D" Control circuit for the inlet air mixer   (according to equipment)
  • "E" Control circuit for the inlet air cooler by-pass mixer
  • "F" Control circuit for the variable geometry turbo
  • "G" Control circuit for the exhaust gas cooler by-pass flap
  • "H" Breather circuit

3. Preliminary operations

CAUTION: Prior to any operation on the vacuum circuit, read the memory of faults and perform the tests as required by the diagnostic tool.

Disconnect the battery.

Remove the engine style cover.

Check the efficiency of the vacuum pump (1).

If the values are not correct: Replace the component that is faulty.

Remove:

Figure b1hdz7gd

Remove the protector: Injection system (12).

Unclip the pipes ()   (at "j").

Remove:

  • The bolts (13)
  • The thermal protector (): electrovalves

4. Checking for leaks

CAUTION: The operation on the electrovalves is done with the help of a mirror.

Checks to be performed depending on the types of problems:

  • If there is a general failure of the vacuum circuit ("d" + "e" + "f" + "g"), refer to the method for checking the sealing of the vacuum reserve (See below)
  • If there is a failure relating to the vacuum circuit controls ("d" + "e" or "f" + "g"), refer to the methods for checking the sealing of the circuit upstream of the electrovalves (See below)
  • If it is a localised problem in the vacuum circuit ("d", "e", "f" or "g"), refer to the methods for checking the sealing of the circuit downstream of the electrovalves (See below)

4.1. Vacuum reservoir

Figure b1hdz6yd

Uncouple: The vacuum pipes   (at "k", "l").

N.B.: Without removing the electrovalves.

Figure b1hdzj2d

Fit a plug [1617-J] in place of the pipe   (at "k").

Connect the manual vacuum pump [DA16] in place of the pipe   (at "l").

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Recommence the operation upstream of the vacuum reserve until the leak has been identified; Replace the component that is faulty

Remove the tools [1617-J], [DA16].

Couple up: The pipes   (at "k", "l").

4.2. Control circuit for the inlet air mixers (Upstream of the electrovalve)

Figure b1hdzj3d

CAUTION: The plug [1617-J] must be in place.

Remove:

Fit a tapered plug [DA16] on the pipe exiting the vacuum reserve.

Connect the manual vacuum pump [DA16] on the second pipe exiting the vacuum reserve.

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty

Remove the closers [DA16], [1617-J]; vacuum-pressure manual pump [DA16].

Refit:

4.3. Control circuit for the inlet air mixing (Downstream of the electrovalve)

Figure b1hdzj4d

Uncouple:

  • The air inlet hose (14)
  • The air inlet hose (15)   (according to equipment)
Figure b1hdzj5d

Remove:

CAUTION: Check one circuit at a time.

Connect the manual vacuum pump [DA16] on the pipe exiting the electrovalve.

CAUTION: Check the movement of the flaps (16), (17), with the aid of a mirror and using the diagnostic tool.

N.B.: Tailgate (17): According to equipment.

Apply a vacuum of 0,5 bar:

  • The vacuum is reached, the flap moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the flap moves with difficulty or not at all; Replace any defective parts

Refit:

  • The air inlet hose (14)
  • The air inlet hose (15)   (according to equipment)
  • Inlet air cooling solenoid valve (6)
  • Inlet air mixer control electrovalve (4) (according to equipment)

4.4. Control circuit for the turbocharger and the exhaust gas cooler by-pass (Upstream of the electrovalve)

Figure b1hdzj6d

Remove:

Uncouple the vacuum pipe ()   (at "l").

Fit a plug [1617-J] in place of the pipe   (at "l").

Figure b1hdzj7d

Fit a tapered plug [DA16] on the pipe exiting the vacuum reserve.

Connect the manual vacuum pump [DA16] on the second pipe exiting the vacuum reserve.

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty

Remove the closers [DA16], [1617-J]; vacuum-pressure manual pump [DA16].

Refit:

4.5. Control circuit for the variable geometry turbo (Downstream of the electrovalve)

Figure b1hdzj8d

Remove: Turbocharger pressure regulation solenoid valve (8).

Connect the manual vacuum pump [DA16] on the pipe exiting the electrovalve.

CAUTION: Check that the control rod (18) on the turbocharger moves, with the aid of a mirror and using the diagnostic tool.

Apply a vacuum of 0,7 bar:

  • The vacuum is reached, the control rod moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the flap moves with difficulty or not at all: Inspect the condition of the pipe exiting the electrovalve as well as the control capsule; Replace any defective parts

Refit: Turbocharger pressure regulation solenoid valve (8).

4.6. Control circuit for the exhaust gas cooler by-pass flap (Downstream of the electrovalve)

Figure b1hdzj9d

Remove: Electrovalve controlling the EGR exchanger by-pass (10).

Connect the manual vacuum pump [DA16] on the pipe exiting the electrovalve.

CAUTION: Check the movement of the control rod (19) on the EGR valve.

Apply a vacuum of 0,5 bar:

  • The vacuum is reached, the control rod moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the flap moves with difficulty or not at all: Inspect the condition of the pipe exiting the electrovalve as well as the control capsule; Replace any defective parts

Refit: Electrovalve controlling the EGR exchanger by-pass (10).

4.7. Refitting

Refit:

  • The thermal protector (): electrovalves
  • The bolts (13)

Clip in place: The tubes (as "j").

Refit:

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Reconnect the battery.

CAUTION: Clear the memory of faults (Using the diagnostic equipment).

Refit the engine style cover.

Parts & tools for this job For 2011 Citroën DS5

As an Amazon Associate we earn from qualifying purchases.