Removing - refitting: Air flow meter
- Make
- Citroën
- Model
- DS5 Factory Workshop Manual
- Year
- 2011–2015
- Section
- Air and fuel supply › Removing - refitting: Air flow meter
Removing - refitting: Air flow meter
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Parts which must always be replaced
| Designation | Quantity |
|---|---|
| Air inlet flow meter seal | 1 |
2. Location
The air flow meter (1) is located on the turbocharger air inlet duct.
3. Removing
Disconnect the ancillaries battery.
Disconnect the connector (at "a").
Slacken the clip (3).
Uncouple and move aside the air duct (2).
Remove:
- The 2 bolts (4)
- The air flow meter(1)
4. Refitting
CAUTION: Lubricate the seal (5).
Refit:
- Seal (5) (new)
- The air flow meter(1)
- The 2 bolts (4)
- The air inlet duct (2)
- The clip (3)
Reconnect the connector (at "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
CAUTION: Delete the fault codes.