Removing - refitting: Oxygen sensors
- Make
- Citroën
- Model
- DS5 Factory Workshop Manual
- Year
- 2011–2015
- Section
- Emission control › Removing - refitting: Oxygen sensors
Removing - refitting: Oxygen sensors
ESSENTIAL: Observe the safety and cleanliness recommendations.
ESSENTIAL: Wait at least one hour before carrying out any work on the exhaust line.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. The use of solvents or contact greases for cleaning the oxygen sensor connector is strictly prohibited.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [4386-T] | slit socket 22 mm |
2. Location: Oxygen sensors
(1) upstream oxygen sensor.
(2) Downstream oxygen sensor.
3. Upstream oxygen sensor
3.1. Removing
Disconnect the ancillaries battery.
Remove:
- The air hose (5)
- The clip (4)
- The bolts (3)
- The turbocharger air outlet union (6)
Unclip the electrical harness (at "b").
Disconnect the connector of the upstream oxygen sensor (1) (at "a").
Unclip the connector from the support.
Remove the upstream oxygen sensor (1); Using tool [4386-T].
3.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
Refit the upstream oxygen sensor (1); Using tool [4386-T].
Clip the connector on its support.
Connect the upstream oxygen sensor (1) connector (at "a").
Clip the electrical harness (at "b").
Refit:
- The turbocharger air outlet union (6)
- The bolts (3)
- The clip (4)
- The air hose (5)
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
4. Downstream oxygen sensor
4.1. Removing
Disconnect the ancillaries battery.
Put the vehicle on a hoist.
Remove the under engine protection (depending on the version).
Disconnect the downstream oxygen sensor (2) connector (at "c").
Unclip the connector from the support.
Remove downstream oxygen sensor (2); Using tool [4386-T].
4.2. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
Refit downstream oxygen sensor (2); Using tool [4386-T].
Clip the connector on its support.
Connect the downstream oxygen sensor connector (2) (at "c").
Refit:
- The protective panel under the engine (depending on the version)
- The vehicle on the ground
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.