Dismantling - re-assembly: Exhaust gas recycling module
- Make
- Citroën
- Model
- DS5 Factory Workshop Manual
- Year
- 2011–2015
- Section
- Emission control › Dismantling - re-assembly: Exhaust gas recycling module
Dismantling - re-assembly: Exhaust gas recycling module
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [0165-2] | Pliers for removing elastic clips |
2. Precaution
CAUTION: Do not separate the exchanger (1) from the valve (2).
The exhaust gas recycling module is assembled at the factory with the aid of a template. Assembling it without using a template would create positioning tensions on the cylinder head, adversely affecting the fixings and the sealings of the module.
3. Removing
Put the vehicle on a hoist.
Disconnect the 12 volt battery.
Remove the engine style cover.
CAUTION: Protect the engine cooling radiator to prevent damage to the fins.
Disconnect the connectors (at "a", "b").
Remove: The air filter housing (3) with the air flow sensor.
Remove the intake air mixer unit (4).
Drain the cooling system.
Remove the intake air mixer unit (4).
Unfasten and move aside: The electric harness transition duct (5).
Remove:
- The mountings (6)
- The inlet air mixer unit support (7)
Remove:
- The dipstick (8)
- The (9) bolt
- The nut (10)
- The dipstick guide (11)
Uncouple:
- The vacuum pipe (as "c")
- The pipe (12) from the cooling circuit; Using tool [0165-2]
Remove:
- The bolts (17)
- The nut (13)
- The nut (14)
- The (15) bolt
- The pillar screw (16)
Remove:
- The stud (18)
- The stud (19)
Tilt the EGR module downwards.
Remove:
- The bolts (20); Using a Torx spanner with extension
- The tube (21)
- The exhaust gas recycling module (22) (Carefully)
4. Refitting
4.1. Preparation
Clean the seal faces of the EGR module, using a special degreaser index 24.
CAUTION: When positioning the seal faces (24), (25), pay particular attention to the retaining studs (risk of leaks).
Refit: New seals (23), (24), (25).
Lubricate: Seal (23); With engine oil.
4.2. Refitting (Continued)
CAUTION: Adhere to the tightening torques.
Refit:
- The exhaust gas recycling module (22)
- The tube (21)
- The bolts (20)
- The stud (19)
- The stud (18)
Tightening procedure: Exhaust gas recycling module.
Finger tighten: The mountings (13)-(14)-(15)-(16)-(17).
Tighten to the specified torque:
- The pillar screw (16)
- The (15) bolt
- The nut (14)
- The nut (13)
- The bolts (17)
Couple up:
- The pipe (12) from the cooling circuit; Using tool [0165-2]
- The vacuum pipe (as "c")
CAUTION: Use engine oil to lubricate the O-ring seals of the dipstick guide tube.
Refit:
- The dipstick guide (11)
- The (9) bolt
- The nut (10)
- The dipstick (8)
- The inlet air mixer unit support (7)
- The mountings (6)
Clip in place: The electric harness transition duct (5).
CAUTION: Remove the protection from the cooling radiator.
Refit the intake air mixer unit (4).
Fill and bleed the cooling system.
Refit the intake air mixer unit (4).
Fill and bleed the cooling system.
Refit: The air filter housing (3) with the air flow sensor.
Connect the connectors (at "a", "b").
Refit the engine style cover.
Return the vehicle to its wheels.
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the 12V battery.
Parts & tools for this job For 2011 Citroën DS5
- TOOLOBD2 scannerSearch: OBD2 scanner
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBack-probe test leadsSearch: back probe test leads
As an Amazon Associate we earn from qualifying purchases.